Operating Instruction GX 3 (01)

Table Of Contents
10 English
3.9 Belt hook
The belt hook can be extended in two stages.
Status Meaning
First position Position for attaching to a waist belt
Second position Position for attaching to ladders, scaffolds,
platforms, etc.
3.10 Gas can
Observe the safety instructions provided with the gas can!
In order to operate the fastening tool, the gas can must be inserted in the gas can compartment.
The gas can status can be read from the LED display after pressing the GAS button.
The gas can must be removed before breaks between working, before maintenance and before transporting
or storing the fastening tool.
3.11 Indication of gas can status
After pressing the GAS button, the LED display indicates the status of the gas can.
The gas level indicator does not operate correctly if the fastener guide / tool nosepeice has been fully
compressed.
Status Meaning
All four LEDs light green. Level is approx. 100 %.
Three LEDs light green. Level is approx. 75 %.
Two LEDs light green. Level is approx. 50 %.
One LED lights green. Level is approx. 25 %.
One LED blinks green. Level is below 10 %. Replacement of the gas
can is recommended.
One LED lights red. There is either no gas can in the fastening tool,
the wrong type of gas can is fitted or the can is
empty.
Even when the level is indicated as “empty”, the gas can, for technical reasons, still contains a little gas.
4 Technical data
4.1 Fastening tool
Weight (empty)
8.6 lb
Application temperature, ambient temperature
14 …113
Maximum fastener length
1.5 in
Fastener diameter
0.10 in
0.12 in
Compression stroke
1.6 in
Magazine capacity
40 + 2 nails
Maximum fastener driving frequency (Fasteners per hour)
1,200