Malfunction Possible cause Action to be taken
The fastener is not driven
deep enough.
The piston is incorrectly
positioned.
Remove the cartridge strip and
clean the tool.
Check the piston and buffer and
replace if necessary.
Bad cartridge. Pull the cartridge strip through
to the next cartridge.
The piston jams in the ex-
haust gas piston return unit.
The piston is damaged. Change the piston.
Rubber dust or debris in the piston
return unit.
Check the piston and buffer and
replace if necessary.
Contact Hilti Service if the
problem persists.
Build-up of combustion residues. Service the tool.
The exhaust gas piston return
unit jams.
Build-up of combustion residues. Service the tool.
No fastener driven: The tool
fires, but no fastener is
driven.
The piston is incorrectly
positioned.
Remove the cartridge strip and
clean the tool.
Check the piston and buffer and
replace if necessary.
The tool cannot be fired.
The tool was not pressed fully
against the working surface.
Press the tool fully against the
working surface.
The magazine is not loaded. Load the magazine.
Plastic fragments in the magazine. Open the magazine, remove the
nail strip and plastic fragments.
The piston is incorrectly
positioned.
Remove the cartridge strip and
clean the tool.
Check the piston and buffer and
replace if necessary.
Nails in the magazine are not cor-
rectly positioned.
Reload the tool.
The piston jams in the fas-
tener guide.
The piston and/or buffer are dam-
aged.
Unscrew the magazine, check
the piston and buffer and
replace if necessary.
Plastic fragments in the magazine. Open the magazine, remove the
nail strip and plastic fragments.
Use of excessively high driving
power on steel.
Reduce the driving power.
Firing the tool at a high power set-
ting without a fastener loaded.
Avoid firing the tool without a
fastener loaded.