Operating Instruction DX 5 (01)
Table Of Contents
- Original operating instructions
- 1 Information about the documentation
- 2 Safety
- 3 Description
- 4 Technical data
- 5 Operation
- 5.1 Safety devices
- 5.2 Loading the single-fastener tool
- 5.3 Loading the magazine tool
- 5.4 Setting the power level
- 5.5 Driving fasteners with the single-fastener tool
- 5.6 Driving fasteners with the magazine tool
- 5.7 Unloading the single-fastener tool
- 5.8 Unloading the magazine tool
- 5.9 Switching Bluetooth on and off
- 5.10 Resetting the cleaning indicator
- 5.11 Procedure if a cartridge fails to fire
- 5.12 Tool misfires (cartridge doesn't fire)
- 6 Care and maintenance
- 6.1 Care of the tool
- 6.2 Maintenance
- 6.3 Servicing the tool
- 6.4 Dismantling the single-fastener tool
- 6.5 Dismantling the magazine tool
- 6.6 Checking the piston and buffer for wear
- 6.7 Checking the fastener guide for wear
- 6.8 Cleaning and lubricating the single-fastener tool
- 6.9 Cleaning and lubricating the magazine tool
- 6.10 Assembling the single-fastener tool
- 6.11 Assembling the magazine tool
- 6.12 Final check of the tool
- 7 Troubleshooting
- 8 Disposal
- 9 Manufacturer’s warranty
- 10 Confirmation of C.I.P. testing
8 English
2. Pull the fastener out of the tool.
5.8 Unloading the magazine tool
1. Pull the cartridges out of the tool.
2. Pull the magazine cover down and remove the fastener strip.
5.9 Switching Bluetooth on and off
▶ Press and hold the pushbutton for 1-2 seconds to switch on Bluetooth.
Note
Bluetooth switches itself off automatically after 2 minutes.
5.10 Resetting the cleaning indicator
▶ Press and hold the pushbutton for 10-12 seconds to reset the cleaning indicator.
Note
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
5.11 Procedure if a cartridge fails to fire
1. Keep the nose of the tool pressed at right angles against the working surface for 30 seconds.
2. If the cartridge still fails to fire, lift the tool away from the working surface. Take care to avoid pointing it
at yourself or other persons.
3. Pull the cartridge strip by hand to advance it to the next cartridge and use up the remaining cartridges
on the strip.
5.12 Tool misfires (cartridge doesn't fire)
WARNING
Heat The tool can get hot through use.
▶ Wear protective gloves.
▶ Allow the tool to cool down.
1. Stop using the tool immediately.
2. Unload and dismantle the tool.
3. Check that you are using the correct combination of magazine, piston and fasteners.
4. Check the buffer, piston and magazine for wear, and replace the parts if necessary.
5. Clean the tool.
◁ If the problem persists after taking the measures described above, further use of the tool is not
permissible.
Printed: 29.09.2017 | Doc-Nr: PUB / 5292580 / 000 / 01