Operating Instruction DX 5 (01)
Table Of Contents
- Original operating instructions
- 1 Information about the documentation
- 2 Safety
- 3 Description
- 4 Technical data
- 5 Operation
- 5.1 Safety devices
- 5.2 Loading the single-fastener tool
- 5.3 Loading the magazine tool
- 5.4 Setting the power level
- 5.5 Driving fasteners with the single-fastener tool
- 5.6 Driving fasteners with the magazine tool
- 5.7 Unloading the single-fastener tool
- 5.8 Unloading the magazine tool
- 5.9 Switching Bluetooth on and off
- 5.10 Resetting the cleaning indicator
- 5.11 Procedure if a cartridge fails to fire
- 5.12 Tool misfires (cartridge doesn't fire)
- 6 Care and maintenance
- 6.1 Care of the tool
- 6.2 Maintenance
- 6.3 Servicing the tool
- 6.4 Dismantling the single-fastener tool
- 6.5 Dismantling the magazine tool
- 6.6 Checking the piston and buffer for wear
- 6.7 Checking the fastener guide for wear
- 6.8 Cleaning and lubricating the single-fastener tool
- 6.9 Cleaning and lubricating the magazine tool
- 6.10 Assembling the single-fastener tool
- 6.11 Assembling the magazine tool
- 6.12 Final check of the tool
- 7 Troubleshooting
- 8 Disposal
- 9 Manufacturer’s warranty
- 10 Confirmation of C.I.P. testing
10 English
◁ If the trigger resistance increases.
◁ If the power regulation wheel is stiff.
◁ If the cartridge strip is difficult to remove.
◁ If the maintenance indicator shows that a tool service is necessary.
6.4 Dismantling the single-fastener tool
1. Check that there is no cartridge strip or fastener in the tool. If there is a cartridge strip or fastener in
the tool, pull the cartridge strip up out of the tool by hand from above and remove the fastener from the
fastener guide.
2. Press the release button on the side of the fastener guide to unscrew the fastener guide.
3. Unscrew and remove the exhaust gas piston return unit.
4. Remove the buffer by bending it sharply out of the fastener guide. Remove the buffer.
5. Remove the piston.
6.5 Dismantling the magazine tool
1. Check that there is no cartridge strip or fastener in the tool. If there is a cartridge strip or fastener in
the tool, pull the cartridge strip up out of the tool by hand from above and remove the fastener from the
fastener guide.
2. Press the release button on the side of the fastener guide to unscrew the magazine.
3. Unscrew and remove the exhaust gas piston return unit.
4. Remove the buffer by bending it sharply out of the magazine. Remove the buffer.
5. Remove the piston.
Printed: 29.09.2017 | Doc-Nr: PUB / 5292580 / 000 / 01