Operating Instruction DX 5 (01)

Table Of Contents
16 English
Malfunction Possible cause Action to be taken
The tool cannot be fired.
Nails in the magazine are not cor-
rectly positioned.
Reload the tool.
The piston jams in the fas-
tener guide.
The piston and/or buffer are dam-
aged.
Unscrew the magazine, check
the piston and buffer and
replace if necessary.
Plastic fragments in the magazine. Open the magazine, remove the
nail strip and plastic fragments.
Use of excessively high driving
power on steel.
Reduce the driving power.
Firing the tool at a high power set-
ting without a fastener loaded.
Avoid firing the tool without a
fastener loaded.
The fastener guide in the
magazine jams.
The magazine is damaged. Replace the magazine.
7.2 Problems with fasteners to be driven into concrete
Malfunction Possible cause Action to be taken
Fastener driving depth varies.
The piston is incorrectly
positioned.
Remove the cartridge strip and
clean the tool.
Check the piston and buffer and
replace if necessary.
The tool has too much built-up dirt
and residues.
Service the tool.
If necessary, have the tool
checked by Hilti Service.
The fastener bends.
Hard surface (steel, concrete). Increase driving power (adjust
power regulating wheel).
Hard aggregates in concrete Use a more powerful cartridge.
Use the single-fastener tool
instead of the magazine tool.
A rebar is located just below the
concrete surface.
Use a shorter nail.
Use a nail with a higher
application limit.
Drive the fastener in at a
different position.
The fastener is not driven
flush.
Wrong fastener. Use a fastener of the correct
length for the insulation thick-
ness.
Wrong power setting. Adjust the power setting on the
tool.
Hard aggregates in concrete Use a more powerful cartridge.
Use the single-fastener tool
instead of the magazine tool.
Printed: 29.09.2017 | Doc-Nr: PUB / 5292580 / 000 / 01