Operating Instruction DX 5 (01)

Table Of Contents
English 5
DX 5
Recommended maximum fastening rate
DX 5
700 rev/h
Application temperature (ambient temperature)
5 …122
(−15 …50 ℃)
Compression stroke
1.3 in
(32 mm)
Pressure required
DX 5
39 lb
f
(≥ 174 N)
4.2 Vibration
The vibration value that must be specified in accordance with 2006/42/EC does not exceed 2,5 m/s².
5 Operation
5.1 Safety devices
Note
Before commencing work, check that all safety devices are fitted and that they are functioning correctly.
All parts must be fitted correctly and fulfill all conditions necessary for the correct operation of the tool.
5.2 Loading the single-fastener tool
1. Push the fastener into the tool from the front until it is held in place in the tool by the fastener’s washer.
2. Push the cartridge strip, narrow end first, into the grip of the tool from below until the full length of the
cartridge strip is inside the tool. If you wish to use a cartridge strip in which some of the cartridges have
already been used, start pulling the strip up and out the top of the tool by hand until the first unused
cartridge is in place in the cartridge chamber.
Printed: 29.09.2017 | Doc-Nr: PUB / 5292580 / 000 / 01