Operating Instruction DX 5 (01)
Table Of Contents
- Original operating instructions
- 1 Information about the documentation
- 2 Safety
- 3 Description
- 4 Technical data
- 5 Operation
- 5.1 Safety devices
- 5.2 Loading the single-fastener tool
- 5.3 Loading the magazine tool
- 5.4 Setting the power level
- 5.5 Driving fasteners with the single-fastener tool
- 5.6 Driving fasteners with the magazine tool
- 5.7 Unloading the single-fastener tool
- 5.8 Unloading the magazine tool
- 5.9 Switching Bluetooth on and off
- 5.10 Resetting the cleaning indicator
- 5.11 Procedure if a cartridge fails to fire
- 5.12 Tool misfires (cartridge doesn't fire)
- 6 Care and maintenance
- 6.1 Care of the tool
- 6.2 Maintenance
- 6.3 Servicing the tool
- 6.4 Dismantling the single-fastener tool
- 6.5 Dismantling the magazine tool
- 6.6 Checking the piston and buffer for wear
- 6.7 Checking the fastener guide for wear
- 6.8 Cleaning and lubricating the single-fastener tool
- 6.9 Cleaning and lubricating the magazine tool
- 6.10 Assembling the single-fastener tool
- 6.11 Assembling the magazine tool
- 6.12 Final check of the tool
- 7 Troubleshooting
- 8 Disposal
- 9 Manufacturer’s warranty
- 10 Confirmation of C.I.P. testing
English 7
5.5 Driving fasteners with the single-fastener tool
1. Position the tool.
2. Hold the tool perpendicular to the working surface and then press it against the surface.
3. Press the trigger to drive the fastener.
5.6 Driving fasteners with the magazine tool
1. Position the tool.
2. Hold the tool perpendicular to the working surface and then press it against the surface.
3. Press the trigger to drive the fastener.
5.7 Unloading the single-fastener tool
1. Pull the cartridges out of the tool.
Printed: 29.09.2017 | Doc-Nr: PUB / 5292580 / 000 / 01