Installation Typicals - Fastening on Steel Threaded Studs
2 studs
4 studs
DOWNLOAD DRAWINGS (PDF) DOWNLOAD DRAWINGS (DWG) FASTENER OVERVIEW
APPLICATION OVERVIEW
DISCLAIMERHOW TO USE THIS DOCUMENT
x
x
FASTENER SYSTEM
FASTENER TECHNICAL DETAILS
Application
• Fastening of cable trays, pipes on a T-Post support, which is fastened on a
horizontal structure
• Support is fastened by two / four X-BT-MF (horizontal distance x)
• L1 is the total width of the T-Post, L2 is fix set to 1000 mm
• Load F is the acceptable total load (all dead load including)
Boundary conditions
• These values are ONLY reflecting capacity of X-BT-MF threaded stud.
Structural analysis of support / structure is NOT in Hilti scope. See the detailed
statements in disclaimer — 2018/05/04
• 2 Load cases: load asymmetric acting in the center of one arm only,
30% acting as horizontal load
Result:
L1 [mm]
F [kg]
50 75 100 125 150 200 250 300
→ Load in [kN] 0.49 0.74 0.98 1.23 1.47 1.96 2.45 2.94
x
[mm]
80
1795
100
2245 1430
125
2805 1785 1275
150
3365 2145 1530
175
3930 2500 1790 1360
200
4490 2860 2045 1555
Result:
Load
F [kg]
L1 [m m]
150 200 250 400 600 800 1000 1200
x
[mm]
80
60 60 60 60 60 60 60 60
100
75 75 75 75 75 75 75 75
125
85 85 85 85 85 85 85 85
150
100 100 100 100 100 100 100 100
175
110 110 110 110 110 110 110 110
200
120 120 120 120 120 120 120 120
Result:
Load
F [kg]
L1 [m m]
150 200 250 400 600 800 1000 1200
x
[mm]
80
35 35 35 35 35 35 35 35
100
40 40 40 40 40 40 40 40
125
50 50 50 50 50 50 50 50
150
60 60 60 60 60 60 60 60
175
65 65 65 65 65 65 65 65
200
75 75 75 75 75 75 75 75
Result:
L1 [mm]
F [kg]
50 75 100 125 150 200 250 300
→ Load in [kN] 0.49 0.74 0.98 1.23 1.47 1.96 2.45 2.94
x
[mm]
80
100
125
1275
150
1530
175
1790
200
2045
NOTE: load capacity used for calculation N
rec
= 1.5 kN (axial) / V
rec
= 2.2 kN (shear)
Technical assessment — maximum of L1 and F (depending on load F or lever arm length L1 and X-BT-MF distance x)
FASTENING T-POST (CEILING) SUPPORT
WITH X-BT-MF
Two / Four X-BT-MF Threaded studs
X-BT-MF • Metric
47Issued August 2018, expiry January 2022