Installation Typicals - Fastening on Steel Threaded Studs

Application
Fastening of junction boxes, switches on a vertical structure
Element is fastened by X-ST-GR
Boundary conditions
These values are ONLY reflecting capacity of X-ST-GR threaded stud.
Structural analysis of support / structure is NOT in Hilti scope. See the detailed
statements in disclaimer 2018/05/04
Technical data are based on technical data binder for X-ST-GR (06 / 2018),
always refer to latest technical data binder for X-ST-GR
Recommended load X-ST
Base material thickness t
II
≥ 6 mm (0.24")
Base material
Steel R
m
≥ 350 MPa
Tension, N
rec
[kN]
1.8
Shear, V
rec
[kN]
1.8
Moment, M
rec
[Nm]
5.5
Technical data always refer to latest technical data binder for X-ST
FASTENING JUNCTION BOXES / SWITCHES
WITH X-ST-GR
X-ST-GR Threaded stud
X-ST-GR • Metric
Application limit
Steel: DX 5, DX 460
Steel thickness, t
II
[mm]
Steel strength, R
m
[N/mm
2
]
20
18
16
14
12
10
8
6
350 400 450 500 550 600 650 700
Steel: DX 76 PTR
Steel strength, R
m
[N/mm
2
]
Steel thickness, t
II
[mm]
350 400 450 500 550 600 650 700
20
18
16
14
12
10
8
6
66Issued August 2018, expiry January 2022