Installation Typicals - Fastening on Steel Threaded Studs

HOW TO USE THIS DOCUMENT
We can utilize the following tables to solve different typical use cases
Application Customer’s typical use cases
F
L1
x
F1
F2
(F3)
(F4)
RL
Use
Case
L1 x F RL Typical customer task
A
?
“I know the loads and use existing
baseplates, I have different lever-arm
length, so what is the maximum L1?”
B
?
“I know loads and the required lever-
arm. I want to minimize the baseplate
size, so what is minimum x?”
C
?
“I already have supports available and
want to know maximum allowable
load, so what maximum F can I use?”
D
?
“I already have supports available
and want to minimize the number of
supports, so how do I use RL for that?”
F1 F4 fasteners
F load on the support
RL resulting load
(tensile and shear load)
L1 support lever length
x support basis
(=distance of fasteners)
✓ Parameter is known; ? Parameter is the table output
It is recommended to position the support lever
half way between the fasteners to ease installation
7Issued August 2018, expiry January 2022