Keep the product, especially its grip surfaces, clean and free from oil and
grease. Do not use cleaning agents containing silicone.
Clean the outside of the product at regular intervals using a slightly
dampened cloth. Do not use a spray, steam pressure cleaning equipment
or running water for cleaning.
Frequent work on conductive materials (e.g. metal, carbon fiber) may
make shorter maintenance intervals necessary. Take your individual
workplace risk assessment into account.
8.1 Checks after care and maintenance work
After carrying out care and maintenance, check that all protective and
safety devices are fitted and that they function faultlessly.
9 Transport and storage
Do not transport the power tool with an accessory tool fitted to it.
Always unplug the supply cord before storing the power tool.
Store the product in a dry place where it cannot be accessed by children
or unauthorized persons.
After long periods of transport or storage, check the power tool for
damage before use.
10 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable
to remedy the problem by yourself, please contact Hilti Service.
10.1 Troubleshooting
Trouble or fault Possible cause Action to be taken
Product does not
start.
Interruption in the elec-
tric supply.
Plug in another power
tool or appliance
and check whether it
works.
The supply cord or plug
is defective.
Have the supply cord
and plug checked by a
trained electrical spe-
cialist and replaced if
necessary.
Printed: 19.10.2018 | Doc-Nr: PUB / 5402266 / 000 / 01