4 Technical data
Note
For details of the rated voltage, current, frequency and/or input power, please refer to the appliance’s
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer’s power output must be at
least twice the rated input power shown on the rating plate of the appliance. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the appliance.
VC 300-17 X
Weight
63.1 lb
(28.6 kg)
Mains connection (type)
SJTWA 3/14 AWG
Maximum volumetric flow rate (air)
2 x 157 CFM (2 x 74 ℓ/s)
Container capacity
17 liq. gal
US
(65 ℓ)
Water capacity
13 liq. gal
US
(48 ℓ)
Suction hose connector (C-DN/C-ID)
1.6 in
(40 mm)
Vacuum (max.)
3.7 psi
(254 mbar)
Ambient temperature (max.)
104 ℉
(40 ℃)
Automatic filter cleaning, all
7.5 s
Protection class
I
Protection class
IPX4
5 Before use
CAUTION
Risk of injury presented by the appliance running away out of control. The vacuum cleaner may
run away out of control if the wheel brakes are not engaged.
▶ Engage the wheel brakes so that the vacuum cleaner stands securely.
5.1 Operating the appliance for the first time
1. Open the two catches.
2. Lift the vacuum cleaner top section away from the waste material container.
3. Remove the accessories and packaging from the waste material container.
4. Fit a suitable dust bag in accordance with the instructions.
5. Fit the vacuum cleaner top section onto the waste material container and close the two catches.
6. Check to ensure that the vacuum cleaner top section is fitted correctly and secured.
7. Connect the suction hose to the appliance.
Printed: 22.02.2017 | Doc-Nr: PUB / 5334135 / 000 / 00