DX 9-HSN DX 9-ENP Quick Start Guide – Supplement
INDEX 2 SAFETY FIRST 3 TOOL ANATOMY 4–6 SELECTING THE RIGHT NAIL, TOOL & CARTRIDGE DOWNLOADING & USING THE HILTI CONNECT APP FASTENING METAL DECK TO THE STEEL STRUCTURE 7 DOWNLOAD ACCESS TOOL INFORMATION INSTALLING THE DECKING NAIL UNDERSTANDING THE SERVICE INDICATOR CONNECTING TO HILTI CONNECT VIA BLUETOOTH KNOWING HOW TO CLEAN THE TOOL KNOWING ESSENTIAL FIELD TROUBLE SHOOTING 8 9 10 – 11 12 13 14 – 15 POSSIBLE CAUSES TOOL STAYS COMPRESSED TOOL CANNOT BE COMPRESSED Additional resources
SAFTEY FIRST 3 INDEX Requirements to be met by the user The tool is intended for professional use. The tool may be operated, serviced and maintained only by trained, authorized personnel who have received special instruction regarding the hazards that may be encountered. Use the tool for the first time only after you have been trained by a Hilti specialist on how to use it safely. Personal Protective Equipment (PPE) Operator and bystanders must wear helmet, eye and ear protection.
TOOL ANATOMY 4 INDEX Handle Trigger Button Cartridge Inlet Housing Cartridge Outlet Nail Release Button Magazine Guide Cartridge Channel Carrying Handle Magazine Release Button Pawl Rotating Sleeve Stop Nail Magazine Pressure Pin Nail Detection Mechanism
TOOL ANATOMY 5 INDEX Service Indicator Grip Pipe Triggering Cable Triggering Cable Retainer Ball Holder Firing Unit Cartridge Channel Compression Spring Cartridge Transport Lever Temperature Sensor Nail Advancement Catch Piston Bearing Sleeve
TOOL ANATOMY 6 INDEX Bearing Sleeve Piston Guide Assembly Slider Piston Piston Stop Piston Piston Brake Nail Magazine Piston Retrainer Kit
SELECTING THE RIGHT NAIL, TOOL & CARTRIDGE 7 INDEX Selecting the right nail, tool and cartridge is a pre-requisite for good quality fastening. In addition, improper selection can lead to excessive wear on the DX 9 deck fastening tool. Select the right nail Select the right nail X-HSN 24 fastener is used for fastening deck to bar joist and light gauge steel structure in the thickness range 1/8” (3.2 mm) to 3/8” (9.6 mm).
DOWNLOADING & USING THE HILTI CONNECT APP DOWNLOAD INDEX App Store Install Go to the Google Play Store or the Apple App Store on your phone or scan the QR code. Search for the Hilti Connect App and install it. +LOWL &RQQHFW +LOWL &RQQHFW Select the country 8 Login If you are an existing user, you can push Login. If you are a new user, you can push register or you can skip the login and use the limited functionality.
DOWNLOADING & USING THE HILTI CONNECT APP ACCESS TOOL INFORMATION $ Customers Owned/ Fleet ̵ ̵ ̵ ̵ ̵ Usage Information Last seen location Purchase information Service information Repair information $ 9 INDEX % Tool on Demand ̵ Usage Information ̵ Last seen location % Call to action Call to action ̵ Request service ̵ Related product ̵ Learn more ̵ Learn more ̵ Related products
FASTENING METAL DECK TO THE STEEL STRUCTURE INSTALLING THE DECKING NAIL INDEX Mark the deck Load the nail Marking the deck is important to fasten on the joist or beam because you cant see the joist or beam when fastening the deck. It is a good practice to always keep the Nail Magazine full.
FASTENING METAL DECK TO THE STEEL STRUCTURE 11 INSTALLING THE DECKING NAIL INDEX Check nail stand off and adjust power level if required Initially, then periodically while fastening, and any time you change base material, use the Power Adjustment Gauge to check the nail stand-off and adjust the tool power level.
FASTENING METAL DECK TO THE STEEL STRUCTURE 12 UNDERSTANDING THE SERVICE INDICATOR INDEX The Hilti DX 9-HSN / DX 9-ENP tool has an integrated digital Service Indicator. The digital Service Indicator on the DX 9 gives real-time feedback on when to clean and service the tool, maximizing productivity on the job. The tools operating temperature range is also displayed, helping you to work at the optimal pace. The gauge shows the optimal operating temperature (i.e. working at optimal installation pace).
FASTENING METAL DECK TO THE STEEL STRUCTURE 13 CONNECTING TO HILTI CONNECT VIA BLUETOOTH Bluetooth Connect Turn on the Bluetooth on your phone. Press the Bluetooth button on the digital Service Indicator > 1 sec. The Bluetooth on the DX 9-HSN/DX p-ENP tool turns off after 2min. Start using the Hilti Connect App On page 9 you'll find the how to use it. INDEX >1 sec.
KNOWING HOW TO CLEAN THE TOOL 14 INDEX Disassamble the tool Remove the cartridge strip and nails before disassembling the tool. a b Clean the tool While cleaning the tool, the Hilti spray should be applied ONLY on the Nail Magazine and NOT inside the tool. a c b Check the Piston and Piston Brake Change if either the Piston or Piston Brake is worn. Change only as a set both Piston and Piston Brake.
KNOWING HOW TO CLEAN THE TOOL 15 INDEX Check the Piston and Piston Stop Change if either the Piston or Piston Stop is worn. Change only as a set both Piston and Piston Stop. a b a b Check the Nail Detection Mechanism Checking the Nail Detection Mechanism will help early diagnosis and limit the tool damage. If damaged send the Nail Magazine to Hilti Tool Service.
KNOWING ESSENTIAL FIELD TROUBLE SHOOTING 16 POSSIBLE CAUSES INDEX There are few instances the tool ceases to function on the jobsite.We identify below problems the customer may encounter, their possible causes and the recommended actions. Tool lifetime can be extended and higher tool performance can be achieved when the tool is cleaned and checked at regular intervals.
KNOWING ESSENTIAL FIELD TROUBLE SHOOTING 17 POSSIBLE CAUSES INDEX X-ENP-19 Issue Visual Criteria Trouble Possible cause Action Nail stand-off too high No piston mark visible, nail head stays off, stand-off too high Deck is not fastened properly to the beam Power setting too low or cartridge not strong enough Dial up power setting or increase strength of cartridge Nail stand-off is OK Washer compressed, piston mark clearly visible, deck flat – no deformation – – – Nail stand-off is too lo
KNOWING ESSENTIAL FIELD TROUBLE SHOOTING TOOL STAYS COMPRESSED INDEX Wait for the tool to cool down Wait for the tool to cool down before troubleshooting the tool. The temperature gauge on the tool can be used as a reference to check if the tool is still hot. Use the scraper and open Rotating Sleeve Tool decompresses Tool should be pointing downwards while opening the Rotating Sleeve. Use only the scraper or a punch. Dont use hammer or stone as it will damage the Rotating Sleeve.
KNOWING ESSENTIAL FIELD TROUBLE SHOOTING 19 TOOL STAYS COMPRESSED INDEX Release the Magazine Guide Disassemble the Nail Magazine a b Replace Piston and Piston Brake / Stop Replace the jammed Piston and Piston Brake/Stop with a new one.
KNOWING ESSENTIAL FIELD TROUBLE SHOOTING TOOL CANNOT BE COMPRESSED INDEX Remove the cartridge Insert the nails One reason why the tool cannot be compressed is the nails are not loaded, or nails are not loaded into the right position. Tip: For DX 9-HSN load 6 nail strips and DX 9-ENP 4 nail strips first and then always load the nails when cartridge strip runs out.
KNOWING ESSENTIAL FIELD TROUBLE SHOOTING TOOL CANNOT BE COMPRESSED INDEX Check movment of Nail Detection Mechanism Check movment of Nail Detection Mechanism Use the scraper and check the movement of the Nail Detection Mechanism. Use the scraper and check the movement of the Nail Detection Mechanism. If Damaged, send the Nail Magazine to Hilti Tool Service Center. If Damaged, send the Nail Magazine to Hilti Tool Service Center.