Operating Instruction ST1800
Table Of Contents
8 English
5.1.3 Removing the depth gauge
CAUTION
Risk of injury The depth gauge may hinder the operator if fitted but not used.
▶ Remove the depth gauge from the tool.
1. Remove the protective sleeve.
2. Pull the depth gauge forward, away from the power tool.
5.1.4 Changing the bit
CAUTION
Risk of injury. The accessory tool may be hot or have sharp edges.
▶ Wear protective gloves when using the power tool and when changing accessory tools.
1. Remove the depth gauge. → page 8
2. Pull the sleeve back and hold it securely.
3. Change the bit.
4. Release the sleeve and allow it to slide forward.
5. Fit the depth gauge. → page 7
5.1.5 Adjusting the depth gauge
5.1.5.1 Screw sealing washer compressed too much
If the screw sealing washer is compressed too much, turn the depth gauge to the right.
5.1.5.2 Screw sealing washer is not compressed enough
If the screw sealing washer is not compressed enough, turn the depth gauge to the left.
Printed: 24.07.2018 | Doc-Nr: PUB / 5300838 / 000 / 03