Operating Instruction DX 9-ENP

Table Of Contents
*2194400*
2194400 English 9
Result 2 / 3
The tool can be pressed fully against the working surface (the spring on the pressure pin is fully
compressed) and a click is heard when the trigger is pressed.
The nail detector in the tool is working correctly and the tool can be used.
Result 3 / 3
The tool can be pressed fully against the working surface (the spring on the pressure pin is fully
compressed) but no click is heard when the trigger is pressed.
Have the tool repaired by Hilti Service.
5.1.3 Loading fastener strips 2
1. Insert 4 fastener strips in the magazine from above.
Materials
Fasteners
XENP 19
2. Press the last fastener strip in until it lies flush with the magazine.
5.1.4 Loading cartridge strips 3
1. Insert the cartridge strips from above in the cartridge loading channel.
Materials
6.8/18 M40 red, black, blue cartridge (see the cartridge recommendation in the instructions for use of
the fasteners)
2. Press the cartridge strip into the cartridge loading channel until it lies flush with the top edge of the
cartridge loading channel.
5.1.5 Opening the rotating sleeve 4
If the fastening tool jams, you can open the cover and expose the mechanism in order to rectify the
possible cause.
Turn the rotating sleeve as far as it will go. Use the scraper or some other tool as an aid, if necessary.
5.1.6 Closing the rotating sleeve 5
If the rotating sleeve is not closed, it is not possible to press the fastening tool fully against the working
surface and, accordingly, the tool cannot be operated.
1. Check whether the slot in the front of the tool is closed.
The slot is not fully closed.
2. Turn the rotating sleeve as far as it will go. Use the scraper or some other tool as an aid, if necessary.
5.2 Operation
5.2.1 Driving fasteners 6
CAUTION
Risk of injury! If the tool is extremely hot (see service indicator display) cartridges may explode due to the
effect of the heat, causing flying fragments.
Remove the cartridges from the tool immediately before breaks between working.
If the cartridges cannot be removed from the tool, lay the tool down and make sure that all persons keep
a safe distance away from the tool (3 meters) until the pointer on the temperature indicator has moved all
the way to the left. Notify Hilti Service immediately.
1. Press the tool fully against the working surface at right angles.