ICC ESR-2184 for X-CX Ceiling Clip Assemblies

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 6
ICC-ES Evaluation Report ESR-2184
Reissued June 2021
This report is subject to renewal June 2023.
www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council
®
DIVISION: 03 00 00—CONCRETE
Section: 03 16 00—Concrete Anchors
DIVISION: 05 00 00—METALS
Section: 05 05 23—Metal Fastenings
DIVISION: 09 00 00—FINISHES
Section: 09 22 16.23—Fasteners
REPORT HOLDER:
HILTI, INC.
EVALUATION SUBJECT:
HILTI LOW-VELOCITY POWDER-ACTUATED X-CX
CEILING CLIP ASSEMBLIES
1.0 EVALUATION SCOPE
Compliance with the following codes:
2018, 2015, 2012 and 2009 International Building
Code
®
(IBC)
2018, 2015, 2012 and 2009 International Residential
Code
®
(IRC)
2013 Abu Dhabi International Building Code (ADIBC)
The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced
in this report are the same sections in the ADIBC.
For evaluation for compliance with codes adopted by the
Los Angeles Department of Building and Safety (LADBS),
see ESR-2184 LABC and LARC Supplement.
Property evaluated:
Structural
2.0 USES
Hilti low-velocity powder-actuated X-CX Ceiling Clip
Assemblies are used as alternatives to cast-in-place
anchors described in IBC Section 1901.3 (2012 IBC
Section 1908; 2009 IBC Section 1911) for placement in
concrete and the welds and bolts used to attach materials
to steel described in IBC Sections 2204.1 and 2204.2,
respectively. For structures regulated under the IRC, the
assemblies may be used where an engineered design is
submitted in accordance with IRC Section R301.1.3.
3.0 DESCRIPTION
3.1 X-CX Ceiling Clip Assemblies:
3.1.1 General: Each X-CX Ceiling Clip Assembly consists
of a steel angle (ceiling clip) premounted on either a Hilti
X-AL-H or X-C powder-actuated fastener. A typical
assembly is illustrated in Figure 1A. See Table 1 for
assembly designations, fastener dimensions, applicable
base materials and applicable load tables.
3.1.2 X-AL-H Fastener: The X-AL-H fastener is formed
from carbon steel and is heat-treated to a nominal core
hardness of 58 HRC. The fastener has a zinc coating
complying with ASTM B633, SC1, Type III. The fastener
has a smooth tapered shank, with a nominal diameter
beyond the taper of 0.177 inch and a head diameter of
0.322 inch.
3.1.3 X-C Fastener: The X-C fastener is recognized in
ESR-1663. It is formed from carbon steel and is heat-
treated to a nominal core hardness of 56 HRC. The
fastener has a zinc coating complying with ASTM B633,
SC1, Type III. The fastener has a smooth straight shank,
with a nominal diameter of 0.138 inch and a head diameter
of 0.322 inch.
3.1.4 Ceiling Clip: The ceiling clip is manufactured from
carbon steel conforming to DIN EN 10346 grade
S280GD with a Z140-N-A-C coating. The clip measures
0.79 inch (20 mm) wide and 0.059 inch (1.5 mm) thick. The
outstanding leg has a tear-shaped hole with a nominal
diameter of 0.3 inch (7.5 mm) through which the ceiling
wire is attached. See Figure 1B for an image of the clip.
3.2 Substrate Materials:
3.2.1 Concrete: Normal weight and sand-lightweight
concrete must comply with IBC Chapter 19 or IRC
Section R402.2, as applicable. The minimum concrete
compressive strength at the time of fastener installation
must be as noted in the applicable allowable load table.
3.2.2 Steel Deck Panels: Steel deck panels must
conform to a code-referenced material standard, with the
minimum thickness and minimum yield and tensile
strengths noted in Table 3. See Figure 2 for panel
configuration requirements.
3.2.3 Steel: Structural steel supports must comply with
the minimum requirements of ASTM A36, ASTM A572
Grade 50 or ASTM A992, and must have the minimum
thickness, yield strength and tensile strength as shown in
Table 4.
4.0 DESIGN AND INSTALLATION
4.1 Design:
4.1.1 Allowable Loads: The applicable allowable load
tables for Hilti ceiling clip assemblies driven into different
base materials may be determined by referencing Table 1.
The most critical applied loads, excluding seismic load
effects, resulting from the load combinations in IBC Section

Summary of content (6 pages)