Pull the chuck back as far as it will go and remove the accessory tool.
Use only the recommended grease supplied by Hilti. Use of unsuitable grease may cause damage
to the product.
5.2 Types of work
WARNING
Risk of electric shock! Severe injury and burns can result if any attempt is made to operate the tool without
an earth/ground conductor and ground fault circuit interrupter correctly connected.
Irrespective of whether mains power or generator power is used, always make sure that an earth/ground
conductor and ground fault circuit interrupter are present in the power supply and that these are correctly
connected.
Do not use the product unless these safety measures are in place and fully operational.
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
Check the appliance’s supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Full approval must be obtained from the site engineer or architect prior to beginning the work.
5.2.1 Chiseling
Set the function selector switch to the position.
6 Care and maintenance
WARNING
Danger of electric shock! Carrying out care and maintenance while the supply cord is connected to the
power outlet presents a risk of serious injuries including burns.
Always unplug the supply cord before carrying out all care and maintenance tasks.
Care
Carefully remove stubborn dirt from the tool.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.