ICC ESR-3027 for Kwik HUS-EZ Screw Anchors in Concrete

ESR-3027
|
Most Widely Accepted and Trusted Page 3 of 20
17.4.3 or ACI 318-11 D.5.3, as applicable, the nominal pullout
strength in cracked concrete may be adjusted according to
Eq.-1:
𝑁
,
ī‹Ž
ķ°†“
īŒđ‘
,ī‡Ĩ
ķ°‡Ą

ī‹Ž
ķ°†“
ī„ļ,ī„šī„´ī„´
ķ°‡ĸ
ī‡Ą
(lb, psi) (Eq-1)
𝑁
,
ī‹Ž
ķ°†“
īŒđ‘
,ī‡Ĩ
ķ°‡Ą

ī‹Ž
ķ°†“
ī„ĩī„ģ.ī„ļ
ķ°‡ĸ
ī‡Ą
(N, MPa)
where f′
c
is the specified concrete compressive strength and
n is the factor defining the influence of concrete compressive
strength on the pullout strength. For the
1
/
4
-inch-diameter
anchor at 1
5
/
8
inches nominal embedment in cracked
concrete, n is 0.3. For all other cases, n is 0.5.
In regions where analysis indicates no cracking in
accordance with ACI 318-19 17.6.3.3, ACI 318-14 17.4.3.6
or ACI 318-11 D.5.3.6, as applicable, the nominal pullout
strength in tension may be adjusted according to Eq-2:
𝑁
,
ī‹Ž
ķ°†“
īŒđ‘
,ī‡¨ī‡Ąī‡–ī‡Ĩ
ķ°‡Ą

ī‹Ž
ķ°†“
ī„ļ,ī„šī„´ī„´
ķ°‡ĸ
ī‡Ą
(lb, psi) (Eq-2)
𝑁
,
ī‹Ž
ķ°†“
īŒđ‘
,ī‡¨ī‡Ąī‡–ī‡Ĩ
ķ°‡Ą

ī‹Ž
ķ°†“
ī„ĩī„ģ.ī„ļ
ķ°‡ĸ
ī‡Ą
(N, MPa)
where f′
c
is the specified concrete compressive strength and
n is the factor defining the influence of concrete compressive
strength on the pullout strength. For the
1
/
4
-inch-diameter
anchor at a nominal embedment of 1
5
/
8
inches in uncracked
concrete, n is 0.3. For all other cases, n is 0.5.
Where values for N
p,cr
or N
p,uncr
are not provided in Table 3,
4 or Table 7 of this report, the pullout strength in tension need
not be considered.
The nominal pullout strength in tension of the anchors
installed in the soffit of sand-lightweight or normal-weight
concrete filled steel deck floor and roof assemblies, as shown
in Figure 12, is provided in Table 5 for KH-EZ, KH-EZ P,
KH-EZ PM, KH-EZ PL, KH-EZ C and KH-EZ CRC and Table
8 for KH-EZ I and KH-EZ E. In accordance with
ACI 318-19 17.6.3.2.1, ACI 318-14 17.4.3.2 or
ACI 318-11 D.5.3.2, as applicable, the nominal pullout
strength in cracked concrete must be calculated according to
Eq-1, whereby the value of N
p,deck,cr
must be substituted for
N
p,cr
and the value of 3,000 psi (20.7 MPa) must be
substituted for the value of 2,500 psi (17.2 MPa) in the
denominator. In regions where analysis indicates no cracking
in accordance with ACI 318-19 17.6.3.3, ACI 318-14 17.4.3.6
or ACI 318-11 5.3.6, as applicable, the nominal strength in
uncracked concrete must be calculated according to Eq-2,
whereby the value of N
p,deck,uncr
must be substituted for N
p,uncr
and the value of 3,000 psi (20.7 MPa) must be substituted for
the value of 2,500 psi (17.2 MPa) in the denominator.
4.1.5 Requirements for Static Steel Shear Capacity, V
sa
:
The nominal steel strength in shear, V
sa
, of a single anchor in
accordance with ACI 318-19 17.7.1.2, ACI 318-14 17.5.1.2
or ACI 318-11 D.6.1.2, as applicable is given in Tables 3, 4
and 7 of this report and must be used in lieu of the values
derived by calculation from ACI 318-19 Eq. 17.7.1.2b,
ACI 318-14 Eq. 17.5.1.2b or ACI 318-11 Eq. D-29, as
applicable. The strength reduction factor,
īĻ
, corresponding to
brittle steel elements must be used. The nominal shear
strength V
sa,deck
, of anchors installed in the soffit of sand-
lightweight or normal-weight concrete filled steel deck floor
and roof assemblies, as shown in Figure 12, is given in Table
5 for KH-EZ, KH-EZ P, KH-EZ PM, KH-EZ PL, KH-EZ C and
KH-EZ CRC and Table 8 for KH-EZ I and KH-EZ E. Shear
values for KH-EZ I are for threaded inserts with F
u
â‰Ĩ 125 ksi.
For use with inserts with F
u
less than 125 ksi, the shear
values are multiplied by the ratio of F
u
of insert and 125 ksi.
4.1.6 Requirements for Static Concrete Breakout
Strength in Shear, V
cb
or V
cbg
: The nominal concrete
breakout strength of a single anchor or group of anchors in
shear, V
cb
or V
cbg
, respectively, must be calculated in
accordance with ACI 318-19 17.7.2, ACI 318-14 17.5.2 or
ACI 318-11 D.6.2, as applicable, with modifications as
described in this section. The basic concrete breakout
strength in shear, V
b
, must be calculated in accordance with
ACI 318-19 17.7.2.2.1, ACI 318-14 17.5.2.2 or ACI 318-11
D.6.2.2, as applicable, using the values of ℓ
e
and d
a
given in
Tables 3, 4 and 7.
For anchors installed in the lower or upper flute of the soffit
of sand-lightweight or normal-weight concrete-filled steel
deck floor and roof assemblies, as shown in Figure 12,
calculation of the concrete breakout strength in accordance
with ACI 318-19 17.7.2, ACI 318-14 17.5.2 or ACI 318-11
D.6.2 is not required.
4.1.7 Requirements for Static Concrete Pryout Strength
in Shear, V
cp
or V
cpg
: The nominal concrete pryout strength
of a single anchor or group of anchors, V
cp
or V
cpg
,
respectively, must be calculated in accordance with
ACI 318-19 17.7.3, ACI 318-14 17.5.3 or ACI 318-11 D.6.3,
as applicable, using the coefficient for pryout strength, k
cp
provided in Tables 3, 4 and 7 and the value of N
cb
or N
cbg
as
calculated in Section 4.1.3 of this report.
For anchors installed in the lower or upper flute of the soffit
of sand-lightweight or normal-weight concrete-filled steel
deck floor and roof assemblies, as shown in Figure 12,
calculation of the concrete pryout strength in accordance with
ACI 318-19 17.7.3, ACI 318-14 17.5.3 or ACI 318-11 D.6.3 is
not required.
4.1.8 Requirements for Seismic Design:
4.1.8.1 General: For load combinations including seismic,
the design must be in accordance with ACI 318-19 17.10,
ACI 318-14 17.2.3 or ACI 318-11 D.3.3, as applicable.
Modifications to ACI 318-19 17.10 or ACI 318-14 17.2.3 shall
be applied under Section 1905.1.8 of the 2021, 2018 and
2015 IBC, as applicable. For the 2012 IBC, Section 1905.1.9
shall be omitted.
The anchors comply with ACI 318 (-19 and -14) 2.3 or
ACI 318-11 D.1, as applicable, as brittle steel elements and
must be designed in accordance with ACI 318-19 17.10.5 or
17.10.6; ACI 318-14 17.2.3.4 or 17.2.3.5; ACI 318-11 D.3.3.4
or D.3.3.5, as applicable.
4.1.8.2 Seismic Tension: The nominal steel strength and
nominal concrete breakout strength for anchors in tension
must be calculated in accordance with ACI 318-19 17.6.1 and
17.6.2, ACI 318-14 17.4.1 and 17.4.2 or ACI 318-11 D.5.1
and D.5.2, respectively, as applicable, as described in
Sections 4.1.2 and 4.1.3 of this report. In accordance with
ACI 318-19 17.6.3.2.1, ACI 318-14 17.4.3.2 or ACI 318-11
D.5.3.2, as applicable, the appropriate value for pullout
strength in tension for seismic loads, N
p,eq
or N
p,deck,cr
described in Tables 3, 4 and 5 for KH-EZ, KH-EZ SS316,
KH-EZ C, KH-EZ C SS316, KH-EZ P, KH-EZ PM, KH-EZ PL
and KH-EZ CRC; and in Tables 7 and 8 for KH-EZ I and
KH-EZ E, must be used in lieu of N
p
. N
p,eq
or N
p,deck,cr
may be
adjusted by calculations for concrete compressive strength in
accordance with Eq-1 of this report in addition for concrete-
filled steel deck floor and roof assemblies the value of
3,000 psi (20.7 MPa) must be substituted for the value of
2,500 psi (17.2 MPa) in the denominator. Where values for
N
p,eq
are not provided in Tables 3, 4 or 7 of this report, the
pullout strength in tension for seismic loads need not be
evaluated.
4.1.8.3 Seismic Shear: The nominal concrete breakout
strength and pryout strength in shear must be calculated
in accordance with ACI 318-19 17.7.2 and 17.7.3,
ACI 318-14 17.5.2 and 17.5.3 or ACI 318-11 D.6.2 and D.6.3,