Operating Instruction DX 351-BT, DX 351-BTG (01)
Table Of Contents
10
en
Cartridge falls out of the
cartridge strip
Cartridge strip melts
9. Troubleshooting
Cartridge doesn’t fire
Cartridge not transported
Cartridge strip cannot be removed
Fault Possible cause
■ Damaged cartridge strip
■ Carbon build-up
■ Tool damaged
■ Bad cartridge
■ Carbon build-up
-WARNING-
Never attempt to pry a cartridge
from the magazine strip or tool.
■ Tool is compressed too long
while fastening.
■ Fastening frequency is too high
■ Fastening frequency is too high
-WARNING-
Never attempt to pry a cartridge
from the magazine strip or tool.
Remedy
■ Clean the cartridge strip guide-
way (see 24)
If the problem persists:
■ Contact Hilti Repair Centre
■ Let the tool cool down and then
carefully try to remove the
cartridge strip (If the problem
persists: Contact Hilti Repair
Center)
■ Contact Hilti Repair Center
■ Manually advance the cartridge
strip one cartridge
■ If the problem occurs more often:
Clean the tool
(If the problem persists: Contact
Hilti Repair Center)
■ Compress the tool only briefly
while fastening.
■ Remove the cartridge strip
■ Disassemble the tool for fast
cooling and to avoid possible
damage
(If the tool cannot be disassem-
bled: Contact Hilti Repair Center)
■ Immediately discontinue using
the tool
■ Remove cartridge strip
■ Let the tool cool down
■ Clean the tool and remove loose
cartridge.
(If it is impossible to disassemble
the tool: Contact Hilti Repair
Center)
■ Tool overheated because of high
setting rate
■ Tool damaged
-WARNING-
Never attempt to pry a cartridge
from the magazine strip or tool.
Printed: 20.08.2013 | Doc-Nr: PUB / 5126352 / 000 / 01