Operating Instruction DX 351-BT, DX 351-BTG (01)

12
en
The thread on the stud is
damaged
Fault Possible cause
Fastener guide damaged
Remedy
Replace the fastener guide.
Stud doesn’t hold in the base
material
Steel base material too thin
(< 8 mm)
Hole damaged or previously used
Driving power too low
Hole not deep enough
Wrong drill bit used
Dirt/debris in hole
Drive studs only on steel base
material 8 mm.
Drill new hole.
Increase driving power.
Drill to correct depth
=> visible ring .
Use correct drill bit
Remove liquids, debris or other
foreign matter from the hole
before installing the stud.
Piston jams in the piston guide Damaged piston
Carbon build-up
Remove the cartridge strip
Piston guide
Check the piston and replace it if
necessary
Clean the tool
Trigger can’t be pulled Tool not pressed fully against the
work surface
Piston fitted incorrectly
Tool defective
Press the tool fully against the
work surface.
Fit the piston correctly.
Contact your Hilti Center.
Printed: 20.08.2013 | Doc-Nr: PUB / 5126352 / 000 / 01