Table 2 - Hilti carbon steel KB-TZ2 design information for hammer and core drilled installations, tension
6
Design
parameter
Symbol Units
Nominal anchor diameter (in)
1/4 3/8 1/2 5/8 3/4 1
Effective min.
embedment
1
h
ef
in. 1-1/2 1-1/2 2 2-1/2 1-1/2 2 2-1/2 3-1/4 2-3/4 3-1/4 4 3-1/4 3-3/4 4-3/4 4 5-3/4
(mm) (38) (38) (51) (64) (38) (51) (64) (83) (70) (83) (102) (83) (95) (121) (102) (146)
Tension, steel failure modes
Strength
reduction factor
for steel in
tension
2
Φ
sa,N
- 0.80 0.80 0.80 0.80 0.80 0.80
Min. specified
yield strength
f
y
lb/in
2
100,900 100,900 96,300 87,000 84,700 75,000
(N/mm
2
) (696) (696) (664) (600) (584) (517 )
Min. specified
ult. strength
f
uta
lb/in
2
122,400 126,200 114,000 106,700 105,900 88,000
(N/mm
2
) (844) (870) (786) (736) (730) (607)
Effective tensile
stress area
A
se,N
In
2
0.024 0.051 0.099 0.164 0.239 0.47
(mm
2
) (15.4) (33.2) (63.6) (106.0) (154.4) (303.2)
Steel strength in
tension
N
sa
lb 2,920 6,490 11,240 17, 5 35 25,335 41,365
(kN) (13.0) (28.9) (50.0) (78.0) (112.7) (184.1)
Tension, concrete failure modes
Strength
reduction factor
for concrete and
pullout failure in
tension
Φ
c,N
,
Φ
p,N
- 0.75 0.75 0.75 0.75 0.75 0.75
Effectiveness
factor for
uncracked
concrete
k
uncr
- 24 24 27 24 24 27 27
5
24 27 24
Effectiveness
factor for
cracked
concrete
6
k
cr
- 17 21 17 24 21 17 21 17 21 21
Modification
factor for anchor
resistance,
tension
3
Ψ
3
- 1.0 1.0 1.0 1.0 1.0 1.0
Pullout strength
uncracked
concrete
4
N
p,uncr
lb 2,10 0
N/A N/A
4,18 0
N/A N/A N/A N/A
5,380
N/A
8,995
N/A N/A N/A N/A N/A
(kN) (9.3) (18.6) (23.9) (40.0)
Pullout strength
cracked
concrete
4
N
p,cr
lb 625
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
8,835
N/A
11, 810
(kN) (2.8) (39.3) (52.6)
Pullout strength
seismic
4
N
p,eq
lb 625
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
8,700
N/A
11, 810
(kN) (2.8) (38.7) (52.6)
Normalization
factor, uncracked
concrete
n
uncr
- 0.20 N/A N/A 0.35 N/A N/A N/A N/A 0.50 N/A 0.50 N/A N/A 0.39 N/A N/A
Normalization
factor, cracked
concrete,
seismic
n
cr
- 0.39 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 0.29 N/A 0.50
Tension, axial stiffness
Axial stiffness
in service load
range
β
uncr
lb/in. 322,360 131,572 158,583 290,360 412,333 199,845
β
cr
lb/in. 31,033 91,336 113,514 167,367 62,179 122,400
For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N, 1 psi = 0.006895 MPa. For pound-inch units: 1 mm = 0.03937 inches.
1
Figure 2 of this report illustrates the installation parameters.
2
The KB-TZ2 is considered a ductile steel element in accordance with ACI 349-01 Appendix B
3
For all design cases, Ψ
3
= 1.0. The appropriate effectiveness factor for cracked concrete (k
cr
) or uncracked concrete (k
uncr
) shall be used.
4
For all design cases, Ψ
4
= 1.0. Tabular value for pullout strength is for a concrete compressive strength of 2,500 psi (17.2 MPa). Pullout strength for concrete
compressive strength greater than 2,500 psi (17.2 MPa) may be increased by multiplying the tabular pullout strength by (f’c / 2,500)
n
for psi, or (f’c / 17.2)
n
for MPa,
where n is given as n
uncr
for uncracked concrete and n
cr
for cracked concrete and seismic. NA (not applicable) denotes that pullout strength does not need to be
considered for design.
5
For core drill installations, k
uncr
= 24 for 3/4-inch diameter anchors installed at 3-3/4 inches (95 mm) effective embedment.
6