Status Meaning
The service indicator blinks red. • The overheating prevention cut-out has been
activated.
• The voltage provided by the electric supply is
too high.
Note
Bring the product to Hilti Service in good time. This will help to ensure that it’s always ready for use.
3.7 Items supplied
Breaker, side handle, operating instructions.
You can find other system products approved for your product at your local Hilti Center or online at:
www.hilti.group.
4 Technical data
4.1 Technical data
Note
For details of the rated voltage, current, frequency and/or input power, please refer to the power tool’s
country-specific type identification plate.
When powered by a generator or transformer, the generator or transformer’s power output must be at least
twice the rated input power shown on the rating plate of the power tool. The operating voltage of the
transformer or generator must always be within +5% and -15% of the rated voltage of the power tool.
TE 1000AVR
Weight
27.6 lb
(12.5 kg)
Single impact energy
26 J
4.1.1 Using extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if
damaged while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance’s supply cord at regular intervals and have it replaced by a qualified specialist
if found to be damaged.
• Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The power tool may otherwise suffer a drop in performance and the extension cord may
overheat.
• Check the extension cord for damage at regular intervals.
• Replace damaged extension cords.
• When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Recommended minimum conductor cross-section and maximum power-cord length for 120V supply
voltage
Cord AWG 16 AWG 14 AWG 12 AWG 10
Conductor cross-section 1,31 mm² 2,08 mm² 3,31 mm² 5,26 mm²
Conductor cross-section 2,58 kcmil 4,11 kcmil 6,53 kcmil 10,4 kcmil
Cord length 25 m 30 m 50 m 100 m
Cord length 75 ft 100 ft 150 ft 250 ft
Printed: 19.07.2017 | Doc-Nr: PUB / 5364048 / 000 / 00