User's Manual

29
3.3 View Grade
Note: This function will appear when the Voice Sense QWERTY is
connected to SyncBraille.
You can choose what grade of Braille you want the Braille display to use
when reading. Words situated in current cursor are output Computer
Braille and remaining characters are output Uncontracted Braille or
Contracted Braille.The shortcut key is “g”. The setting choices are
“Uncontracted Braille”, “Contracted Braille”, and “Computer Braille”. You
can switch between the settings by pressing the “Space”. You can press
“Fn-g” to cycle through the three settings while you are using other
programs without calling up the “Global options”. If you have changed
the setting, press the “Enter” to save the setting.
You can also “tab” or “shift-tab” to the “Confirm” button, and press
“Enter.” If you do not want to save the setting, “tab” or “shift-tab” to the
“Cancel” button, and then press “Enter.” You can also cancel saving the
setting by pressing “Alt-F4” or “ESC.”
3.4 Message Display Time
Note: This function will appear when the Voice Sense QWERTY is
connected to SyncBraille.
You can choose when a Braille message will disappear from the Braille
display. This setting will only work when the voice setting is set to “Off”.
But “Stand by” and “Ignore” execute when the voice setting is set to “On”.
The shortcut key is “m.” The setting options that you can choose from
are “Stand by,” “Ignore”, and 1 to 10 seconds. The default is “3
seconds.” The “Space” increases the option by one second and the
“Backspace” decreases the option by one second. You can set the unit
to standby mode by pressing the “Space” until you reach “Stand by.” In
this mode, the message will remain until you press a key. The higher
value you select, the longer the message remains. If you read the
message before setting the number of seconds, you can clear the