Installation Instruction

Page 9
1. Technical Data
Host
Rated Voltage 12V – 48V DC
Dimension / Weight 120 x 120 x 61(mm) / 0.60 lb
Working Temperature
14° to 122° Fahrenheit (if below -8° Fahrenheit, must order special battery)
Frequency & Range
UWB (Ultra-Wide Band) 3.5G-6.5Ghz; No License Fees Required
Range: 10-70 feet
Tags Limit Maximum P-Tags Detecting: 30
Antenna Built-in
Shell Enclosure ABS, with metal plate
Gross Weight ~ 1.61 lb
P-Tag
Power Supply Embedded 500mAh Lithium battery
Dimension 40×40×15(mm)
Working Temperature
14° to 122° Fahrenheit (if below -8° Fahrenheit, must order special battery)
Frequency & Range
UWB (Ultra-Wide Band) 3.5G-6.5Ghz; No License Fees Required
Range: 10-70 feet
Antenna Built-in
Enclosure ABS
Gross Weight ~ 0.92 oz
Accessories
Host Power Cable Length (m) 9.84 ft
P-Tag AC/DC Adapter
Input 100–245V~50/60Hz
Output Voltage 5V/1A
Environmental Indoor use only
Alarm Flash Light
Dimension 73×73X46(mm)
Voltage 12V DC
Environmental Rain proof
Audio Speaker
Dimension 102×102×124(mm)
Voltage 12V DC
Environmental Rain proof
2. Host:
2.1 Working Temperature: 14° to 122° Fahrenheit. The host may not work beyond this temperature range.
2.2 Default Set of Alarming Distance in factory: 30 feet. The user may adjust the alarming distance by turning
the knob on the Host. The alarming distance is designed from 10to 70’ in increments of 10’. After adjusting
the Distance Knob, please wait for 30 seconds, so that the host finishes setting.