Instructions / Assembly

H I N K L E Y L I G H T I N G 12600 Berea Road Cleveland, OH 44111 800.446.5539 / 216.671.3300 www.hinkleylighting.com
installation instructions
Family: 120V Series Spot Light Item No. 55000 BZ
1. Find a clear area in which you can work.
2. Carefully review instructions prior to assembly.
3. Gather tools required: WIRE STRIPPERS, PHILIPS HEAD SCREWDRIVER,
SILICONE GREASE, THREAD SEALANT.
• Save these instructions for future reference.
start here
55000
WARNING: LUMINAIRE MUST BE INSTALLED AND GROUNDED IN ACCORDANCE
WITH THE NATIONAL ELECTRICAL CODE (NEC) AND LOCAL CODES. FOR PORTABLE
STAKE OR SUFACE MOUNT USING A CORD AND PLUG, THE LUMINAIRE MUST BE
PLUGGED INTO A RECEPTACLE PROTECTED BY A GROUND FAULT CIRCUIT
INTERRUPTER (GFI). FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY
AND/ OR DAMAGE TO THE LUMINAIRE.
ALWAYS USE UL RECOGNIZED WIRE CONNECTORS FOR CONNECTIONS.
IN GROUND LUMINAIRE IS ETL LISTED FOR ABOVE GRADE INSTALLATION ONLY.
SAFETY WARNING: LUMINAIRE CAN BECOME VERY HOT DEPENDING ON THE
LAMP WATTAGE USED. LENS AND HOUSING AROUND THE LAMP CAN BECOME
HOT ENOUGH TO BLISTER HANDS. PARTICULAR CARE SHOULD BE TAKEN NOT TO
LOCATE LUMINAIRES WHERE SMALL CHILDREN CAN REACH THEM IF HIGH
WATTAGE LAMPS ARE USED.
MAINTENANCE NOTE: TO ASSURE PROPER OPERATION AND EFFICIENCY AND TO
PREVENT LUMINAIRE OVERHEATING, LENS MUST BE KEPT CLEAN AND FREE OF
DIRT, LEAVES, TRASH, AND MINERAL DEPOSITS FROM WATER. A REGULAR
SCHEDULE MAINTENANCE PROGRAM IS RECOMMENDED.
1. Please refer to the mounting instructions located on the back of this sheet to
continue installation of this fixture.
lamp installation replacement
1. To prevent electrical shock, disconnect from the electrical supply before servicing.
2. Loosen set screw from shroud assembly.
3. Remove shroud assembly to expose lamp.
4. Replace lamp with correct wattage and type marked on fixture label.
CAUTION: DO NOT EXCEED MAXIMUM WATTAGE MARKED ON LUMINAIRE LABEL.
5. Re-install shroud assembly and tighten set screw.
6. After lamp is installed supply power to the luminaire and check for proper operation.
Info 55000 BZ: Lamp Type is Par 38 or R-40
Maximum Wattage is 175 watts per bulb.
3.4.08