User Guide

33
4.1 Setting an NVP Value
索引
4
3
2
1
7
6
5
10
9
8
Setting Procedure
5.
Press the key to measure the cable length.
6.
Change the NVP value with the S / T keys so that the
displayed length matches the measured physical length
of the standard reference cable.
7.
Press the key to display the Confirmation screen,
select "OK" with the S / T keys, press the key again
to accept your setting.
8.
Select "Measurement" with the S / T keys, and press
the key to return to the Test screen.
TES
T
The cable length measure
-
ment range of this instru-
ment is 2 to 300 m (6.6 to
984-ft.).
(In this example, "100.0 m
"
has been selected)
NVP value
SE
T
SE
T
SE
T