Data Sheet
PC Software
High-Voltage measurement for use with power supply
DIFFERENTIAL PROBE 9322
For up to 2 kV DC or 1 kV AC. Use
with either AC Adapter 9418-15, or
Probe Power Unit 9687 and Power
Cord 9248.
AC ADAPTER 9418-15
For powering Differential probe
9322, 100 to 240 V AC
POWER CORD 9248
to connect Differential probe
9322 and Probe power unit 9687,
70 cm (2.3 ft) length
PROBE POWER UNIT 9687
Factory-installed option - not user installable,
built in on the bottom case. Simultaneously
power up to 8 units of Differential Probe
9322. (Max. 3 A output)
Logic signal measurement
MEMORY HiCORDER 8861-50
*
The MEMORY HiCORDER
8861-50
cannot operate alone. You must
install one or more optional input modules in the unit.
*
When ordering,
specify two memory boards of the same capacity for the
8861-50
.
MEMORY HiCORDER 8860-50
*
The MEMORY HiCORDER
8860-50
cannot operate alone. You must
install one or more optional input modules in the unit.
*
When ordering,
specify one memory board for the
8860-50
.
Configuration of options
Note: Options described as ”factory-installed options” must be specified when ordering and cannot be installed by the user. Note: Product names appearing in this catalog are trademarks or registered trademarks of various companies.
3269
3273-50
3276
3274
3275
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
POWER SUPPLY 3272
Connect and power up to one CLAMP
ON PROBE to use in combination with
voltage input modules
POWER SUPPLY 3269
Connect and power up to four CLAMP
ON PROBEs to use in combination
with voltage input modules
PROBE POWER UNIT 9687
Factory-installed option - not user installable, built
in on the bottom case. Simultaneously power up
to at least 5 units of Clamp on Probes 3273-50 to
3276 or Differential Probe 9322. (Actual number
depends on combination of probes.)
*
Either the DC power unit 9684 or the probe
power unit 9687 may be used. If you want to
use both at the same time,
consult us.
3272
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.5
μsec, miniature terminal type)
LOGIC PROBE 9321-01
4 isolated channels, ON/OFF
detection of AC/DC voltage
(miniature terminal type)
LOGIC PROBE 9327
4-channel type, for voltage/contact signal
ON/OFF detection (response time 0.1
μsec or higher, miniature terminal type)
CONVERSION CABLE 9323
Used for connecting the 9320/9321 and
8860 series MEMORY HiCORDERs,
because the terminal shapes are different.
* This cable is not required for the small-
terminal types 9327, 9320-01, and
9321-01.
Voltage measurement for use with general input modules
CONNECTION CORD 9790
(Thin Type) CAT II 300 V, ultra-
flexible 2.8 mm (0.11 in) diameter test
lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
ALLIGATOR CLIP 9790
-01
Red/black set attaches to the ends
of test leads (9790)
GRABBER CLIP 9790
-02
Red/black set attaches to the ends
of test leads (9790)
CONTACT PIN 9790-03
Red/black set attaches to the ends
of test leads (9790)
CONNECTION CORD 9197
For high voltage (up to 500 V), 1.8 m
(5.91 ft) length
CONNECTION CORD 9198
For low voltage (up to 300 V), 1.7 m
(5.58 ft) length
10:1 PROBE 9665
Max. rated voltage to earth is same as
for input module, max. input voltage 1
kV rms (up to 500 kHz), 1.5 m (4.92 ft)
length
100:1 PROBE 9666
Max. rated voltage to earth is same as
for input module, max. input voltage 5
kV peak (up to 1MHz), 1.5 m (4.92 ft)
length
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8956
HIGH RESOLUTION UNIT 8957
16ch SCANNER UNIT 8958
DC/RMS UNIT 8959
STRAIN UNIT 8960
HIGH VOLTAGE UNIT 8961
..................Maximum 4 units in one MEMORY HiCORDER 8861-50
ANALOG UNIT 8936
VOLTAGE/TEMP UNIT 8937
FFT ANALOG UNIT 8938
STRAIN UNIT 8939
F/V UNIT 8940
4ch ANALOG UNIT 8946
CHARGE UNIT 8947
Recommended
Recommended
A4 PRINTER UNIT 8995
Factory-installed option. Either 8995 or
8995-01 printer can be installed. Printing
width 200 mm (7.87 inch).
RECORDING PAPER 9231
(for A4-printer 8995 only)
A4 width 216 mm (8.50 in) × 30
m (98.43 ft), 6 rolls
RECORDING PAPER 9234
(for A6-printer 8995
-01 only)
A6 width 112 mm (4.41 in) × 18
m (59.06 ft), 10 rolls
A6 PRINTER UNIT 8995-01
Factory-installed option. Either 8995 or
8995-01 printer can be installed. Printing
width 100 mm (3.94 inch).
Not CE marked
Printer options
PAPER WINDER 220H
Paper width 70 to 220 mm (2.76
to 8.66 inch), 100 V AC Only
Recommended
Tip Expanders
Attachment clips are sold separately
from CONNECTION CORD 9790.
Purchase the appropriate attachment
clips for your application separately
Tip Expanders
9790
-01
Tip Expanders
9790
-03
Tip Expanders
9790
-02
Recommended Recommended
SENSOR UNIT 9555-10
Power supply unit for the 9272 to
the 9279 clamp sensors, except
for connecting to the F/V unit
8940, for signal output 9217 is
necessary.
CONVERSION CABLE 9318
(to connect the 9272 - 9279
and the 8940)
F/V UNIT 8940
UNIVERSAL CLAMP ON CT
9277
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 20A /
output 2V AC
UNIVERSAL CLAMP ON CT
9278
Observe waveforms from DC to distorted
AC. DC to 100kHz response, input 200A /
output 2V AC
UNIVERSAL CLAMP ON CT
9279
Observe waveforms from DC to distorted
AC. DC to 20kHz response, input 500A /
output 2V AC
CLAMP ON SENSOR
9272
-10
Enables observation of AC current
waveforms. Input: 1 to 100kHz, selectable
20 and 200A rms ranges, 2V AC output
CONVERSION CABLE 9705
Use with the Conversion Cable 9318
to connect Model 9272-10 to the F/V
Unit 8940. (Not necessary for when
using the Model 9272 due to different
output wiring specifications.)
Not CE marked
CONVERSION CABLE 9318
to connect the 9272 to 9279 and the 8940
3273-50
Current measurement *Connect directly to the analog input module
DC POWER UNIT 9684
Factory-installed option - not user
installable, built in on the bottom case.
12 V DC drive.
MEMORY BOARD 9715-50
(32 Megaword capacity)
MEMORY BOARD 9715-51
(128 Megaword capacity)
MEMORY BOARD 9715-52
(512 Megaword capacity)
MEMORY BOARD 9715-53
(1 Gigaword capacity)
Note: Memor y boards are not built in as a
standard feature. Choose one boa rd for
Model 8860-50, and two of the same capacity
for the 8861-50, for factory pre-installation.
HD UNIT 9718-50
Factory-installed option. 60 GB
MEMORY BACKUP UNIT
9719-50
Factory-installed option. Internal type.
*
Only one of either
the DC Power Unit 9684
or Probe Power Unit 9687
can be installed at any one time. Please contact
your HIOKI representative if concurrent instal-
lation is required.
CONNECTION CORD 9217
Cord has insulated BNC connectors at
both ends, and connects to insulated
BNC connectors on input module.
1.7 m (5.58 ft) length
CONNECTION CORD 9165
Cord has metallic BNC connectors at
both ends, and connects to metallic BNC
connectors. 1.5 m (4.92 ft) length
LAN CABLE 9642
Straight Ethernet cable, supplied
with straight to cross conversion
cable, 5 m (16.41 ft) length
CARRYING CASE 9723
For only the 8860-50/8860, hard
trunk type
CARRYING CASE 9724
For only the 8861-50/8861, hard
trunk type
MEMORY HiVIEWER 9725
Functions identical to those of the 8860s.
Windows 2000/XP, Windows Vista (32-bit type)
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC
terminal on Input Module
Other options
FlexPro
FlexPro is a powerful data analysis and presentation
software for importing and organizing data from the
8860
-50 / 8861-50 Series.
WAVE PROCESSOR 9335
Convert data, print and display waveforms.
Note: Supports 8860-50/8860, 8861-50/8861 series
MEM, REC and REC&MEM data recorded using
single-axis sampling only.
Product Company:
Weisang GmbH (Germany)
Contact:
Email: info@weisang.com
URL: http://www.weisang.com/
Windows95/98/Me, NT4.0/2000/
XP, Windows Vista (32-bit)
Recommended
Removable storage (CF card)
Supplied with PC
Card adapter
PC CARD 256M 9727
(256 MB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC Card Precaution
Use only PC Cards sold by HIOKI.
Compatibility and performance
are not guaranteed for PC cards
made by other manufacturers. You
may be unable to read from or save
data to such cards.
Not CE marked
Combination example (1)
Main unit with memory 32 MW
No. of CH.
2 ch + logic 16 ch 4 ch + logic 16 ch 6ch + logic 16ch 8ch + logic 16ch
Combination example (2)
Main unit with memory 32 MW
No. of CH.
10 ch + logic 16 ch 12 ch + logic 16 ch 14ch + logic 16ch 16ch + logic 16ch
(normal choice of the input unit,
up to 200V AC direct input.)
8860-50 × 1
Input module
8956 × 1 8956 × 2 8956 × 3 8956 × 4
(normal choice of the input unit,
up to 200V AC direct input.)
8861-50 × 1
Input module
8956 × 5 8956 × 6 8956 × 7 8956 × 8
Memory Board 9715-50 × 1
Input cable
9198 × 2 9198 × 4 9198 × 6 9198 × 8
Memory Board 9715-50 × 2
Input cable
9198 × 10 9198 × 12 9198 × 14 9198 × 16
Input modules
Input cables are not supplied. Please purchase the appropriate cable for the intended application.
Current measurement
* To connect the clamp-on sensor via the conversion cable, The
3274, 3275, and 3276 cannot be used for the F/V UNIT 8940
CONVERSION CABLE 9319
To connect the 3273-50 and the 8940
Note: cannot be used with the 3274, 3275,
3276 to connect the 8940 via this cable
9319
CLAMP ON PROBE 3273-50
DC to 50MHz wideband response,
mA-class current up to 30A rms