User Manual

8.14 Searching a Waveform
218
Operating Key Procedure
Setting Analog Channel Search Criteria
5
Select the criteria number to use.
CURSOR
F1 to F8
Move the cursor to the [No.] item.
Select a number for this set of search criteria,
from Analog 1 to Analog 8.
6
Select which timebase to search (if measured using two
timebases).
CURSOR
F1 to F8
Move the cursor to the [Axis] item.
Select either choice.
7
Select the trigger search type
CURSOR
F1 to F8
Move the cursor to the [] item.
Select the type of trigger criteria to use for
searching.
8
Select the type of trigger criteria to use for searching.
CURSOR
F1 to F8
Move the cursor to the [Unit], [Ch] item and select
the channel to be searched.
Only those channels that were recorded using
the [Axis] can be selected.
9
Select the search criteria.
CURSOR
F1 to F8
Select the trigger search criteria.
Available selections depend on the search type.
To combine different search criteria with logical [AND] or [OR],
repeat steps 5 to 9 to specify all necessary criteria.
Displayed items depend
on the trigger type.
7
8
When the trigger
type is [Level]
6
5
9
Timebase 1 Searches a Timebase 1 channel (de
-
fault setting).
Timebase 2 Searches a Timebase 2 channel.
T
Level, Win-In, Win-Out, Off (default setting)
Lvl
(Level)
Set the signal level (threshold voltage
)
for search.
Searching is applied when the signa
l
crosses this level.
Slp
(Slope)
Select the slope (input signal rising
or falling ) for search.
Flt
(Filter)
Set the filter width (trigger filter) fo
r
search. Prevents noise from causin
g
false triggers ( p. 143).
Up
(upper limit)
Low
(lower limit)
Select whether to search for upper o
r
lower limit values.
Trigger search criteria settings are the
same as the pre-measurement trigger cri-
teria settings.
See "6.7 Triggering by Analog Signals"
(
p. 140)