System 1000 Power VentSystem 1000 Power Vent Initializing the ControllerInitializing the Controller 2020
System 1000 Power Vent
Remote Fan Drive Unit
POS
CNTRL
IN OUT
Monitor
AC HOT
CNTRL IN
Light/VAR Monitor Alarm Pressure
LO
L1
N.C.
Com
N.O. Yellow Red BLK
12 AMP
VAR Speed
Stage 8
Stage 7 Stage 6 Stage 5
Out
In
In In In In
Out Out Out Out
FAN
MOTOR
2 AMP
2 AMP
2 AMP
2 AMP
HOT
AC To FAN
Terminals on
controller labeled
In
Out
Fan
Motor
Breaker Panel
Hot
120 VAC or
240 VAC
Variable Speed Wiring
When wiring the Variable speed fans, connect the "hot line" from the
breaker panel to the terminal positions marked "Variable Speed In" on the
board in the bottom of the controller. From the Out connection, run a wire to
the fan motor.
For operation with the Remote Fan Drive Unit, you will need to wire the
system as shown below.
Recommended Wire Gauge for LOW VOLTAGE hookup.
Component HHI Wiring Part
No.
Recommended Wire
Sensor 1502-2427 18/2 Shielded Cable
Hall Effect Devices 1502-2427 18/2 Shielded Cable
PVR-H 1503-1508 18/3 Cable SJT