User Manual
System 1000
Power Vent Controller
9
Programming Guide
Sample Setup
This section is given as an example of how to program the controller for your
individual needs. For this example the house is set up with one controller
operating two power units. Each power unit controls the vents on its respective
side.
Fans
Power UnitsVents Vents
In the above example, one controller is operating two power units. Each
When programming the controller, you should scroll through the menu with the
Select Features up arrow. When you do this, you will see a statement or
question. These statements are known as prompts. You then use the Change
setting up and down arrows to answer these prompts. Here is an example:
Prompt Answer
Ramp function Yes
*Hi end temp 80
*Hi end press .0400
*Lo end temp 30
*Lo end press .0900
Synchronize **Yes
Clock Set time
High Pressure Alarm on Yes
*High pressure .1500
Low Pressure Alarm on Yes
*Low pressure .0000
Timer fan pressure alarm Yes
*Minimum pressure .0200
*Timer period 10 min
*Auto reset alarm No
Differential .0100
Calibrate Temperature If needed
Vent Time Delay Yes
*Delay Seconds 40
• The prompts with an asterisk will not appear when the feature immediately
preceding is answered "No".
• ** Used only when one controller is operating two power units. If only one
power unit is used, answer "No" to this prompt.