Manual
33
LogicPLUS-S Two-Wire Controller
33
PROBLEM SOLUTIONS
Display is ashing “Rain Off”. Power is being supplied to Rain 
Off connector.
Incorrect Rain Switch.
Controller displaying 
reads “Valve Short” with a valve 
number.
High current draw during valve 
run time.
1) Possible bad solenoid.
2) Shorted wires between
 receiver and solenoid.
3) Possible bad receiver.
Display frozen, does not 
respond to rotating valve.
Micro is locked. 1) Turn power off for a minute, 
then back on.
2) Perform a Master Clear.*
Display reads ‘SPD Board Not 
Attached”.
Controller does not sense SPD 
board.
1) Interface cable not connected
2) Bad Connector/Cable, reset 
connectors
Valves Turning ON/OFF during 
run time.
Possible EMF interference Check: Controller, Receivers 
and Field Wiring location in 
respect to any high voltage.