B- AC power cables and exciter’s grounding
Connect the AC feeding pigtail to the identified 3-pin connector located in the left side of the
each Digital Exciter drawer’s rear panel.
Figure 3-49
AC Input cable, ON/OFF switch and fusible - Module 40153
Connect the grounding mesh in the GND screw on the rear panel of each digital exciter.
SCREW GROUNDING
Figure 3-50
Screw grounding - Digital Exciters
GND: Ground - Connect this terminal to ground at the installation site.
EXCITER B
EXCITER A
EXCITER B
EXCITER A