User's Manual

Table Of Contents
USER
MANUAL
MPD-1611291-A
EXACT-V2 High End Rack Modulator / Exciter
3/10/2017
MPD-1611291-A
Page 16/94
o Manual mute and programmable mute condition on LORS
o RF maintain function on stream input loss
Clock and synchronization signal management
o External reference sources: 1PPS, 10MHz inputs
o Onboard GPS (VX20-x0x2)
o 10 MHz reference output
o LORS management
Measurement/Monitoring
o ATSC1.0: MER and shoulder level monitoring (indicative)
o 2 dedicated inputs for forward and reflected powers measurement
AGC feature
o Capacity to automatically adjust the output power to ensure a stable
system output power
o Feedback input using direct adapted RF signal from amplifier output (-
10dBm) or VDC signal from external power sensor
Control and Management
o Control and monitoring via web based GUI
o LCD front panel for main features control and monitoring
o 4 front panel status LEDs
o Alarm relays
o 1+1 Redundacy proprietary management
o 2 Ethernet control ports on rear panel
o 1 Ethernet control ports on front panel
Transmitter Environment Interface
o Full control/monitoring using seamless
Web GUI
o Based on Hitachi-Comark serial protocol
and integrated serial port
Other
o 110-240 VAC
o 1RU rack form factor
Note: Availability of features
depends on software
release version.
(Please refer to the
product release
notes).