Page 47/94
Monitoring Output
x 1
General
Function:
Monitoring output
Standards:
ATSC
Name:
Monit Out
Connector:
SMA50
Type:
Output
Performances
Frequency:
See RF Output
Level:
-20 dB (relative to RFout)
Other:
Monitoring Output (with OPT-
20dB internal preamplifer)
x 1
General
Function:
Monitoring output
Standards:
ATSC 1.0 / ATSC 3.0
Name:
Monit Out
Connector:
SMA50
Type:
Output
Performances
Frequency:
See RF Output
Level:
-43 dB (relative to RFout)
Other:
Monitoring signal from modulator
board (before amplifier)
Figure 33: Monitoring output