User's Manual

Table Of Contents
USER
MANUAL
MPD-1611291-A
EXACT-V2 High End Rack Modulator / Exciter
3/10/2017
MPD-1611291-A
Page 50/94
TOD
x 1
General
Function:
Control / monitoring
Standards:
1x RS-232
Name:
Serial Port 1
Connector:
Female SubD9
Type:
RS-232/RS-485
Performances
Control Baud rate:
TOD Baud rate:
9600 bps to 115200 bps
9600 bps
Other:
No parity, 8 bits data,
1 bit stop
PIN
Name
Dir
1
RS232 Tx
Out
2
Rfu
3
TOD Rx
In
4
RS232 Rx
In
5
GND
6
RS485 Rx+
In
7
RS485 Rx-
In
8
RS485 Tx+
Out
9
RS485 Tx-
Out
Shield
GND
Figure 37: TOD/RS232 Port
The information containing Time Of Day (TOD) is available on Tekelec GPS with the following
characteristics:
ASCII, 9600 bps, 8bits, 1 stop bit, no parity
Protocole <message> <CR> <LF>
Format day/year hour:minute:seconds e.g. 317/1996_18:16:20
The content of message should read “GPS reference” and not “UTC reference” or “local time.