3.5.7 RF and monitoring outputs
Characteristics Typical Value Comment
RF Output
Adjustable Frequency
Range:
Step Size:
Accuracy:
470 to 862 MHz
170 to 240 MHz
54 to 88 MHz
1 Hz
0.2 Hz
Impedance: 50 ohms
Output Level:
Main Signal:
Stability:
Return Loss:
Attenuation Range:
Attenuation Step:
Monitoring Signal:
(Relative to Main Output)
0 dBm ± 1 dB
+20 dBm ± 1 dB
± 0.1 dB / 10 °C
> 13 dB
> 12 dB
0 to 17 dB
0.1 dB
-20 dB ± 2 dB
-40 dB ± 2 dB
EXACT-V2
EXACT-V2-20dB
EXACT-V2-20dB
EXACT-V2
EXACT-V2-20dB
EXACT-V2
EXACT-V2-20dB
EXACT-V2
EXACT-V2-20dB