Parts List/Tune Up Info

REV A — 25 April, 2019
4
Technical Service Bulletin 190425
10. Crest Factor Optimization Parameter Setting
For a given “Crest Factor”, the “Crest Factor Optimization” enhances the signal shoulders. Find-
ing the best value for this parameter allows the user to gain performance on the shoulders of the
signal, thus optimizing the amplier power.
This shoulder optimization involves a MER / SNR performance reduction. The user must nd the
best trade-o󰀨 for shoulder performance vs. MER/SNR performance.
This parameter can vary in a range from 0 (O󰀨 or None) to 255 (Max).
When the Crest Factor Optimization parameter is increased, the shoulder level becomes better.
At the same time, the MER performance decreases. As explained earlier, a trade-o󰀨 between
the two is necessary to obtain the best overall optimization and desired signal performance.
There is a “usable” range for the Crest Factor Optimization parameter between about 50 and
150. Below 50 on this setting not too much e󰀨ect is noticed. Above 150 on this setting the MER
/ SNR performance will likely be too far degraded.