User manual

Hitachi hard disk drive specifications
222
11.43 Standby (E2h/96h)
Command Block Output Registers
Command Block Input Registers
Register
7
6
5
4
3
2
1
0
Register
7
6
5
4
3
2
1
0
Data
-
-
-
-
-
-
-
-
Data
-
-
-
-
-
-
-
-
Feature
-
-
-
-
-
-
-
-
Error
…See Below…
Sector Count
V
V
V
V
V
V
V
V
Sector Count
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Sector Number
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder Low
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Cylinder High
-
-
-
-
-
-
-
-
Device/Head
1
-
1
D
-
-
-
-
Device/Head
-
-
-
-
-
-
-
-
Command
1
1
1
0
0
0
1
0
Status
…See Below…
Error Register
Status Register
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
CRC
UNC
0
IDN
0
ABT
T0N
AMN
BSY
RDY
DF
DSC
DRQ
COR
IDX
ERR
0
0
0
0
0
V
0
0
0
V
0
V
-
0
-
V
Table 164 Standby Command (E2h/96h)
The Standby command causes the device to enter the Standby Mode immediately, and set auto power down
timeout parameter (standby timer).
When the Standby mode is entered, the drive is spun down but the interface remains active. If the drive is
already spun down, the spin down sequence is not executed.
During the Standby mode the device will respond to commands, but there is a delay while waiting for the spindle
to reach operating speed.
The automatic power down sequence is enabled and the timer starts counting down when the drive returns to
Idle mode.
Output Parameters To The Device
Sector Count
Timeout Parameter. If zero, the timeout interval (Standby Timer) is NOT disabled. If
non-zero, then the automatic power down sequence is enabled, and the timeout
interval is shown blow: