Datasheet

7K500 OEM Specification
Page 97 of 176
Word Content Description
89 xxxxH
Time required for security erase unit completion
Time= value(xxxxh)*2 [minutes]
90 xxxxH
Time required for Enhanced security erase completion
Time= value(xxxxh)*2 [minutes]
91 40xxH
Current Advanced Power Management level
15- 8 (=40h)
Reserved
7- 0 (=xxh)
Currect Advanced Power Management level set by Set
Features Command (01h to FEh)
92 xxxxH
Current Master Password Revision Codes
93 0000H
Reserved
94 80xxH
Automatic Acoustic Management value
15-8
Vendor’s Recommended Acoustic Management level
7-0
Current Automatic Acoustic Management value
Default value is FEh
95 0000H
Stream Minimum Request Size
96 0000H
Streaming Transfer Time – DMA
97 0000H
Streaming Access Latency – DMA and PIO
98-99 0000H
Streaming Performance Granularity
100-103 Note.2
Maximum user LBA address for 48-bit Address feature set
104 0000H
Streaming Transfer Time - PIO
105-106 0000H
Reserved
107 8848H
Inter seek delay time (1.5tt + 2.5tl)
108-111 XXXX
World Wide Name
112-118 0000H
Reserved
119 401CH
Supported Setting
15 (=0)
Always
14 (=1)
Always
13-6 (=0)
Reserved
5 (=0)
1=Free-fall Control feature set is supported
4 (=1)
1=Download Microcode with mode 3 is supported
3 (=0)
1=Read and Write DMA Ext GPL is supported
2 (=1)
1=WRITE UNCORRECTABLE is supported
1 (=0)
1=Write Read Verify feature set is supported
0 (=0)
Reserved
120 401CH
Enabled Setting
15 (=0)
Always
14 (=1)
Always
13-6 (=0)
Reserved
5 (=0)
1=Free-fall Control feature set is enabled
4 (=1)
1=Download Microcode with mode 3 is supported
3 (=0)
1=Read and Write DMA Ext GPL is supported
2 (=1)
1=WRITE UNCORRECTABLE is supported
1 (=0)
1=Write Read Verify feature set is enabled
0 (=0)
Reserved
121-126 0000H
Reserved
127 0000H
Removable Media Status Notification feature set
Note.1 The ‘*’ mark in ‘Content’ field indicates the use of those parameters that are vendor specific.
Table 62 Identify device information --- Continued ---