31
The trigger and CCD mode timing can be combined to obtain image timing as indicated in the figures.
a) MODE: MODE1, CCD MODE: FLD
External trigger pulse
EVENODD
Video signal output
EVENODD
W E pulse output
SYNC resetSYNC reset
more than 2 fields
Exposure time
TRIGGER POLARITY:
POSITEVE
TRIGGER POLARITY:
NEGATEVE
more than 64μs
WE POLARITY:
POSITEVE
WE POLARITY:
NEGATEVE