Instruction Manual INVERTER J300U Series

12-10
Display
(Function mode 1) (Function mode 2)
Setting, change
sequence
Function Function Initialization display Initialization
contents
Setting contents
No. name contents
19 F-26 Frequency LIMIT L 0000.0 Hz 0 Hz 0 to 120.0 The lower limit of the
frequency
Frequency
lower limiter
(400) Hz to be set is set. When the lower
limiter setting limit is 0, the setting is invalid.
Frequency LIMIT H 0000.0 Hz 0 Hz 0 to 120.0 The upper limit of the
frequency
upper (400) Hz to be set is set. When the upper
limiter limit is 0, the setting is invalid.
setting
20 F-27 Jump JUMP F1 0000.0 Hz 0 Hz 0 to 400 Hz The section where frequencies
Jump frequency are to be jumped is set.
frequency setting (1) Up to three locations can be
set.
When the number of locations
is 0, the setting is invalid.
Jump JUMP F2 0000.0 Hz 0 Hz 0 to 400 Hz
frequency
setting (2)
Jump JUMP F3 0000.0 Hz 0 Hz 0 to 400 Hz
frequency
setting (3)
Jump JUMP W 0.5 Hz 0.5 Hz 0 to 9.9 Hz The frequency width where
frequency frequencies are jumped is set.
width setting
21 F-28 STOP key STOP-SW ON ON ON: STOP key Whether or not to make the
validity valid STOP key valid during terminal
selection OFF: STOP key running is selected. In the
during invalid Remote mode, the STOP key is
terminal always valid.
running
22 F-29 Running F/R SW FRE FRE FWD/REV/ FWD: Only forward run
direction FRE REV: Only reverse run
selection FRE: Both forward run and
reverse run valid
Reverse run F/R PREV OFF OFF ON/OFF Reverse run prevention
prevention ON:
selection OFF:
Reduced F/R RVS 6 6 0 to 6
voltage
soft start
setting
23 F-30 Maximum F-MAX-L 120 Hz 120 Hz 120/400 Hz Maximum frequency switching:
frequency 120: 120 Hz 400: 400 Hz
selection
24 F-31
Analog input
IN ANA 10 V 10 V 10/5 Input voltage maximum level
External voltage 10: Max. 10 V 5: Max. 5 V
analog selection
frequency External IN EXS 0000.0 Hz 0 Hz 0 to 120.0 (400) Frequency at which the
command frequency external input starts
start setting
External IN EXE 0000.0 Hz 0 Hz 0 to 120.0 (400) Frequency at which the
frequency external input is maximized
end setting
External IN EX%S 000% 0% 0 to 100 Input start level
frequency
start setting
rate
External fre-
IN EX%E 100% 100% 0 to 100 Input maximum level
quency end
setting rate
External IN LEVEL 0 Hz 0 Hz 0 Hz/ExS EXS: Start at EX%S setting
command rate or less
start point
selection