User Manual

Chapter 13 Option
13 - 32
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
(WOP)
Name Description
Initial dat
a
standard
200/400
Initial dat
a
CHN
200/400
Initial dat
a
EU
200/400
Units
A076
(PV source
select)
PV source
Selects source of
Process Variable
(PV), option codes:
01[O/OI] terminal
02Modbus
network
10Calculate
function output
01
A077
(Reverse PID
action)
Reverse PID action
Two option codes:
00PID input =
SP-PV
01PID input =
-(SP-PV)
00
A078
(PID limit)
PID variation
range
Sets the limit of PID
output as percent of
full scale,
range is 0.0 to
100.0%
0.0
%
A081
(AVR select)
AVR function select
Automatic (output)
voltage regulation,
selects from three
type of AVR
functions, three
option codes:
00AVR enabled
01AVR disabled
02AVR enabled
except during
deceleration
02
01 02
A281
(AVR
select-M2)
AVR function select,
2
nd
motor
02 01 02
A082
(AVR voltage
sel)
AVR voltage select
200V class inverter
settings:
200/215/220/23
0/240
400V class inverter
settings:
380/400/415/440/
460/480
200/
400
220/
380
230/
400
V
A282
(AVR voltage
sel-M2)
AVR voltage select,
2
nd
motor
200/
400
220/
380
230/
400
V
A083
(AVR filter
time)
AVR filter time constant
Define the time
constant of the AVR
filter, range is 0.000
to 1.000 seconds.
0.030
s
A084
(OED voltage
gain)
AVR deceleration gain
Gain adjustment
of the braking
performance,
range is 50 to
200%
100.
%
A085
(Energy-savin
g mode)
Energy-saving
operation mode
Two option codes:
00Normal
operation
01Energy-saving
operation
00
A086
(Energy-savin
g tune)
Energy-saving mode
tuning
Range is 0.0 to
100.0 %.
50.0
%
A092
(Accel.time2)
Acceleration time (2)
Duration of 2
nd
segment of
10.00
s