User Manual
Chapter 13 Option
13 - 33
“A” Function
Run
Mode
Edit
Defaults
Func.
Code
(WOP)
Name Description
Initial dat
a
standard
200/400
Initial dat
a
CHN
200/400
Initial dat
a
EU
200/400
Units
A292
(Accel.time2-
M2)
Acceleration time (2),
2
nd
motor
acceleration, range
is:
0.00 to 3600.00
seconds.
10.00
← ←
s
A093
(Decel.time2)
Deceleration time (2)
Duration of 2
nd
segment of
deceleration, range
is:
0.00 to 3600.00
seconds.
10.00
← ←
s
A293
(Decel.time2-
M2)
Deceleration time (2),
2
nd
motor
10.00
← ←
s
A094
(Acc2/Dec2
sel)
Select method to switch
to Acc2/Dec2 profile
Three options for
switching from 1st to
2nd accel/decel:
002CH input from
terminal
01Transition
frequency
02Forward and
reverse
00
← ←
A294
(Acc2/Dec2
sel-M2)
Select method to switch
to Acc2/Dec2 profile,
2
nd
motor
00
← ←
A095
(Acc1-2 FQ)
Acc1 to Acc2 frequency
transition point
Output frequency at
which Accel1
switches to Accel2,
range is 0.00 to
400.00 Hz
0.00
← ←
Hz
A295
(Acc1-2
FQ-M2)
Acc1 to Acc2 frequency
transition point, 2
nd
motor
0.00
← ←
Hz
A096
(Dec1-2 FQ)
Dec1 to Dec2
frequency transition
point
Output frequency at
which Decel1
switches to Decel2,
range is 0.00 to
400.00 Hz
0.00
← ←
Hz
A296
(Dec1-2
FQ-M2)
Dec1 to Dec2
frequency transition
point, 2
nd
motor
0.00
← ←
Hz
A097
(Accel.curve
select)
Acceleration curve
selection
Set the
characteristic curve
of Acc1 and Acc2,
five options:
00linear
01S-curve
02U-curve
03Inverse
U-curve
00
← ←
A098
(Decel.curve
select)
Deceleration curve
selection
Set the
characteristic curve
of Dec1 and Dec2,
options are same as
above (A097)
00
← ←
A131
(Accel.curve
const)
Acceleration curve
constant
Range is 1 to 10
2
← ←
A132
(Decel.curve
const)
Deceleration curve
constant
Range is 1 to 10
2
← ←