9.3 Warning Codes for Digital operator
The warning code for Digital operator is follows.
It is not displayed with the standard panel.
The inverter displays a warning code when the data set as a target function code satisfies the condition
(specified in the Condition column) in relation to the data set as the corresponding basic function code.
Warning
code
Condition
 Frequency upper limit setting (A061) Maximum frequency setting (A004)
 Frequency lower limit setting (A062) Maximum frequency setting (A004)

Output frequency setting (F001),
multispeed 0 (A020) (note 1)
Maximum frequency setting (A004)

Output frequency setting (F001),
multispeed 0 (A020) (note 1)
Frequency upper limit setting (A061)
 Fequency lower limit setting (A062)
Output frequency setting (F001), multispeed 0 (A020)
(note 1)
 Start frequency adjustment (b082) Frequency upper limit setting (A061)
 Start frequency adjustment (b082) Fequency lower limit setting (A062)
 Start frequency adjustment (b082)
Output frequency setting (F001), multispeed 0 (A020)
(note 1)
 Start frequency adjustment (b082) Jog frequency setting (A038)

Output frequency setting (F001),
multispeed 0 (A020) (note 1)
Jump (center) frequency settings 1/2/3 ± " Jump
(hysteresis) frequency width settings 1/2/3"
A063 ± A064, A065 ± A066, A067 ± A068

Multispeed 1 to 7 settings (A021 to
A027)
 Free-setting V/f frequency (7) (b112) Frequency upper limit setting (A061)
 Free-setting V/f frequency (7) (b112) Fequency lower limit setting (A062)
 Free-setting V/f frequency (7) (b112)
Output frequency setting (F001), multispeed 0 (A020)
(note 1)
 Frequency upper limit setting (A261) Maximum frequency setting (A204)
 Frequency lower limit setting (A262) Maximum frequency setting (A204)

Output frequency setting (F001),
multispeed 0 (A220) (note 1)
Maximum frequency setting (A204)

Output frequency setting (F001),
multispeed 0 (A220) (note 1)
Frequency upper limit setting (A261)
 Fequency lower limit setting (A262)
Output frequency setting (F001), multispeed 0 (A220)
(note 1)
 Start frequency adjustment (b082) Frequency upper limit setting (A261)
 Start frequency adjustment (b082) Fequency lower limit setting (A262)
 Start frequency adjustment (b082)
Output frequency setting (F001), multispeed 0 (A220)
(note 1)

Output frequency setting (F001),
multispeed 0 (A220) (note 1)
Jump (center) frequency settings 1/2/3 ± " Jump
(hysteresis) frequency width settings 1/2/3"
A063 ± A064, A065 ± A066, A067 ± A068
 Free-setting V/f frequency (7) (b112) Frequency upper limit setting (A261)
 Free-setting V/f frequency (7) (b112) Fequency lower limit setting (A262)
 Free-setting V/f frequency (7) (b112)
Output frequency setting (F001), multispeed 0 (A220)
(note 1)
Note1)These parameters are checked, even when the digital operator (02) is not specified for the frequency source
setting (A001).

























