User Manual

Chapter 12 Specifications
12 - 5
12.3 Derating Curves
Use the following derating curves to help determine the optimal carrier frequency setting for your inverter
and find the output current derating. Be sure to use the proper curve for your particular NE-S1 inverter
model number.
Become all the production after August, 2012 when Restricted Distribution is China or Europe.
Legend for Graphs:
Ambient temperature 30 max.
Ambient temperature 40 max.
Ambient temperature 50 max.
Rated output current (A)
Production:after August, 2012
2468 10 12 16 140
Carrier frequency(kHz)
1.0
NES1-002SB
1.5
0.5
O
utput
C
urrent
(
Ambient 40
Ambient 50
2 4 6 8 10 12 16 140
1.0
Carrier frequency(kHz)
2.0
NES1-004LB
3.0
O
utput current
(
Ambient 40
Ambient 50
2468 10 12 16 140
1.0
Carrier frequency(kHz)
2.0
NES1-004SB
3.0
O
utput current
(
Ambient 40
Ambient 50
Carrier frequency(kHz)
2 4 6 8 10 12 16 140
1.0
NES1-002LB
1.5
0.5
O
utput current
(
A
)
Ambient 40
Ambient 50
1.4 1.4
2.6 2.6