User Manual

Chapter 13 Option
13 - 4
A
” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description
Initial dat
a
standard
200/400
Initial dat
a
CHN
200/400
Initial dat
a
EU
200/400
Units
A001
Frequency
source
Five options; select codes:
00 POT on ext. operator
01 Control terminal
02 Function F001 setting
03 Modbus network input
10 Calculate function output
01
A201
Frequency
source,
2
nd
motor
01
A002
Run
command
source
Three options; select codes:
01 Control terminal
02 Run key on keypad,
or digital operator
03 Modbus network input
01
A202
Run
command
source,
2
nd
motor
01
A003
Base
frequency
Settable from 30.0 Hz to the maximum
frequency(A004)
60.0 50.0
50.0
Hz
A203
Base
frequency,
2
nd
motor
Settable from 30.0 Hz to the 2
nd
maximum
frequency(A204)
60.0 50.0
50.0
Hz
A004
Maximum
frequency
Settable from the base
frequency to 400.0
60.0 50.0
50.0
Hz
A204
Maximum
frequency,
2
nd
motor
Settable from the 2
nd
base
frequency to 400.0
60.0 50.0
50.0
Hz
A011
[O/OI] input
active
range start
frequency
The output frequency corresponding to
the analog input range starting point,
range is 0.00 to 400.00
0.00
Hz
A012
[O/OI] input
active
range end
frequency
The output frequency corresponding to
the analog input range ending point,
range is 0.0 to 400.00
0.00
Hz
A013
[O/OI] input
active
range start
voltage
The starting point (offset) for the active
analog input range,
range is 0. to 100.
0.
%
A014
[O/OI] input
active
range end
voltage
The ending point (offset) for the active
analog input range,
range is 0. to 100.
100.
%
A015
[O/OI] input
start
frequency
enable
Two options; select codes:
00Use offset ( value)
01Use 0Hz
01
A016
Analog
input filter
Range n = 1 to 31,
1 to 31 :•2ms filter
31. 8 31 Spl.
A019
Multi-speed
operation
selection
Select codes:
00...Binary operation
(8 speeds selectable with 3 terminals)
01...Bit operation
(4 speeds selectable with 3 terminals)
00
A020
Multi-speed
freq. 0
Defines the first speed of a multi-speed
profile, range is 0.00 / start frequency to
400.0
A020 = Speed 0 (1st motor)
0.00
Hz