A
” Function
Run
Mode
Edit
Defaults
Func.
Code
Name Description
Initial dat
a
standard
200/400
Initial dat
a
CHN
200/400
Initial dat
a
EU
200/400
Units
A046
Voltage
compensati
on gain for
automatic
torque
boost
Sets voltage compensation gain under
automatic torque boost, range is 0. to 255.
100.
A246
Voltage
compensati
on gain for
automatic
torque
boost, 2
nd
motor
100.
A047
Slip
compensati
on gain for
automatic
torque
boost
Sets slip compensation gain under
automatic torque boost, range is 0. to 255.
100.
A247
Slip
compensati
on gain for
automatic
torque
boost, 2
nd
motor
100.
A051
DC braking
enable
Three options; select codes:
00Disable
01Enable during stop
02Frequency detection
00
A052
DC braking
frequency
The frequency at which DC braking
begins, range is from the start frequency
(b082) to 60.00Hz
0.50
Hz
A053
DC braking
wait time
The delay from the end of controlled
deceleration to start of DC braking (motor
free runs until DC braking begins),
range is 0.0 to 5.0 seconds.
0.0
s
A054
DC braking
force for
deceleratio
n
Level of DC braking force, settable
from 0 to 100%
50.
%
A055
DC braking
time for
deceleratio
n
Sets the duration for DC braking, range is
from 0.0 to 10.0 seconds.
0.5
s
A056
DC braking
/ edge or
level
detection
for [DB]
input
Two options; select codes:
00Edge detection
01Level detection
01
A057
DC braking
force at
start
Level of DC braking force at start, settable
from 0 to 100%
0.
%
A058
DC braking
time at start
Sets the duration for DC braking, range is
from 0.0 to 10.0 seconds.
0.0
s
A059
Carrier
frequency
during DC
braking
Carrier frequency of DC braking
performance, range is from 2.0 to 15.0kHz
2.0