Operating Guide

12
English
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Do not connect
air hose
Trigger
Push lever
(2) REMOVE ALL NAILS FROM NAILER.
DO NOT push or rest Push Lever against any surface.
DO NOT FORCE OR USE TOOLS TO OPERATE
SWITCH.
Select SINGLE SEQUENTIAL ACTUATION MODE
according to the following steps.
1
Open the change stopper by pushing the bottom of
trigger.
2
Grasp the change rod between two ngers (one on
each side of the trigger) and slide it down (Single
Sequential Actuation Mode.)
3
Con rm that the change stopper has completely
returned to original position inside the trigger.
(SINGLE SEQUENTIAL ACTUATION MECHANISM).
Push The Change stopper
1
Grasp The
Change Rod
2
3
Position of
Change Rod
(3) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm
2
).
Connect the air hose.
THE NAILER MUST NOT LEAK AIR.
(4) Remove the nger from the trigger and press the
push lever against the wood.
THE NAILER MUST NOT OPERATE.
Do not pull
trigger
Depress
push lever
(5) Separate the push lever from the wood.
Next, point the nailer downward, pull the trigger and
then wait in that position for 5 seconds or longer.
THE NAILER MUST NOT OPERATE.
Pull trigger
(6) First pull the Trigger.
Next, depress the Push Lever against the wood.
THE NAILER MUST NOT OPERATE.
000Book_NT65A5_US.indb 12000Book_NT65A5_US.indb 12 2018/05/11 10:24:312018/05/11 10:24:31