Instruction Manual
Table Of Contents
- 1 Safety summary
- 2 Switch Names and Functions
- 3 Operation
- 4 Icon Description
- 5 Function Menu
- 5.1 Simple Timer Setting
- 5.2 Operation Schedule Setting
- 5.3 Power Savings Setting
- 5.4 Night Quiet Operation
- 5.5 Power Saving/Night Quiet Schedule Setting
- 5.6 Power Consumption Display
- 5.7 Autoboost (QUICK MODE) Setting
- 5.8 Comfort Setting
- 5.9 Motion sensor setting
- 5.10 Setback Setting
- 5.11 Elevating Grille
- 5.12 Filter Reminder Reset Setting
- 5.13 FrostWash
- 5.14 Individual Louver Setting
- 5.15 Cancel Individual Louver Setting
- 5.16 Louver Open/Close
- 5.17 Ventilation
- 5.18 Total Heat Exchanger Setting
- 6 Service & installation menu
- 6.1 Installation menu
- 6.1.1 Test Run
- 6.1.2 Function selection
- 6.1.3 Thermistor Selection
- 6.1.4 Input / Output Setting
- 6.1.5 Thermistor Calibration in Controller
- 6.1.6 Fan Speed at Cooling Thermo-OFF
- 6.1.7 Fan Speed at Heating Thermo-OFF
- 6.1.8 Indoor Unit Address Change
- 6.1.9 Address Check Operation
- 6.1.10 Address Initialization
- 6.1.11 Setting Initialization
- 6.1.12 Main Remote Setting
- 6.1.13 Priority Setting
- 6.1.14 Cancel Preheating Control
- 6.1.15 Elevating grille Setting
- 6.1.16 Power Up Setting
- 6.1.17 Setback Trigger Unit
- 6.1.18 Refrigerant Leak Sensor Setting
- 6.2 Service menu
- 6.3 Check Menu
- 6.1 Installation menu
- 7 Screen Display Setting menu
- 8 Contact Information menu
- 9 Hotel Mode Setting
- 10 In Alarm Condition
(Grey)
4 Back light check
03: Back light check
04: Run indicator check
Press “
” on Wired Remote Controller. Back light brightness
gradually increases.
5 Run indicator check
Press “
” on Wired Remote Controller. Run indicator lights
from red to green.
6 Switch input check
Ⓐ
Press each switch once a time. The switches sequence is as
follows: “
”→“ ”→ “ ”→ “ ”→ “ ” → “OK” → “ ”
The number in area indicated with Ⓐ increases by 1 with
each switch pressing.
? NOTE
• The number increases regardless of the order of the switch pressing.
• The switch pressing is not counted if 2 or more switches are pressed
simultaneously.
7 Buzzer check
Press “
” on Wired Remote Controller. Buzzer volume
gradually increases.
06: Buzzer check
07: Transmission check
8 Transmission check
Wired Remote Controller then automatically starts
transmission checking.
9 Thermistor check
The temperature on the remote controller thermistor is
shown in area indicated with Ⓐ .
Ⓐ
10 RTC check
SERVICE & INSTALLATION MENU