User Manual
Table Of Contents
- Front_page_ErP2013
- TC_Clause
- 00_CONTENTS_ErP_2013
- 01_SYSTEM_DESCRIPTION_ErP2013(190313-draft_10C1a)
- 02_GENERAL_DATA_ErP2013(draft2D)
- 03_DIMENSIONAL_DATA_ErP2013(done)
- -DIMENSIONAL DATA
- MONOZONE / MULTIZONE Indoor Units
- MONOZONE / MULTIZONE Outdoor Units
- MONO SPLIT
- WALL TYPE: RAK-18PSA/25PSA/35PSA/18PSAN/25PSAN/35PSAN
- WALL TYPE: RAC-18WSA/25WSA/35WSA/18WSAN/25WSAN/35WSAN
- WALL TYPE: RAK-18PSPA/25PSPA/35PSPA
- WALL TYPE: RAC-18WSPA/25WSPA/35WSPA
- WALL TYPE: RAK-25PXA/35PXA/50PXA
- WALL TYPE: RAC-25WXA/35WXA
- WALL TYPE: RAC-50WXA
- WALL TYPE: RAK-18PPA/25PPA/35PPA
- WALL TYPE: RAC-18WPA/25WPA
- WALL TYPE: RAC-35WPA
- WALL TYPE: RAK-50PPA
- WALL TYPE: RAC-50WPA
- WALL TYPE : RAK-60PPA
- WALL TYPE: RAC-60WPA
- WALL TYPE: RAK-70PPA
- WALL TYPE: RAC-70WPA
- WALL TYPE: RAK-18PEA/25PEA/35PEA/50PEA
- WALL TYPE: RAC-18WEA/25WEA
- WALL TYPE: RAC-35WEA
- WALL TYPE: RAC-50WEA
- FLOOR TYPE: RAF-25PXA/35PXA/50PXA
- FLOOR TYPE: RAC-25FXA/35FXA
- FLOOR TYPE: RAC-50FXA
- FLOOR TYPE: RAF-25RPA/35RPA/50RPA
- FLOOR TYPE: RAC-25FPA/35FPA
- FLOOR TYPE: RAC-50FPA
- DUCT TYPE: RAD-50PPA/60PPA/70PPA
- DUCT TYPE: RAC-50DPA/60DPA/70DPA
- -DIMENSIONAL DATA
- 04_CAPACITIES_AND_SELECTION-ErP2013(DRAFT04)_3
- 05_WORKING_RANGE_ErP2013(23042012-done)
- 06_ELECTRICAL_DATA_ErP2013(Done)
- 07_A_ELECTRICAL_WIRING_DIAG-ErP2013(draft-03)
- ELECTRICAL WIRING DIAGRAM
- MONOZONE/MULTIZONE
- RAK-18QXA, RAK-25QXA, RAK-35QXA, RAK-50QXA
- RAK-18QPA, RAK-25QPA, RAK-35QPA, RAK-50QPA
- RAF-25QXA, RAF-35QXA, RAF-50QXA
- RAF-25RPA, RAF-35RPA, RAF-50RPA
- RAI-25RPA, RAI-35RPA, RAI-50RPA
- RAD-18RPA, RAD-25RPA, RAD-35RPA, RAD-50RPA
- RAC-25NPA, RAC-35NPA, RAC-50NPA
- RAM-36NP2A
- RAM-53NP2A
- RAM-53NP3A
- RAM-68NP3A
- RAM-70NP4A
- RAM-90NP5A
- RAM-130NP6A (OUTDOOR 1)
- RAM-130NP6A (OUTDOOR 2)
- MONO - SPLIT
- RAK-18PSA, RAK-25PSA, RAK-35PSA
- RAK-18PSAN, RAK-25PSAN, RAK-35PSAN
- RAC-18WSA, RAC-25WSA, RAC-35WSA, RAC-18WSAN, RAC-25WSAN, RAC-35WSAN
- RAK-18PSPA, RAK-25PSPA, RAK-35PSPA
- RAC-18WSPA, RAC-25WSPA, RAC-35WSPA
- RAK-25PXA, RAK-35PXA, RAK-50PXA
- RAC-25WXA, RAC-35WXA
- RAC-50WXA
- RAK-18PPA, RAK-25PPA, RAK-35PPA
- RAC-18WPA, RAC-25WPA
- RAC-35WPA
- RAK-50PPA
- RAC-50WPA
- RAK-60PPA
- RAC-60WPA
- RAK-70PPA
- RAC-70WPA
- RAK-18PEA, RAK-25PEA, RAK-35PEA, RAK-50PEA
- RAC-18WEA, RAC-25WEA
- RAC-35WEA
- RAC-50WEA
- RAF-25PXA, RAF-35PXA, RAF-50PXA
- RAC-25FXA, RAC-35FXA
- RAC-50FXA
- RAF-25RPA, RAF-35RPA, RAF-50RPA
- RAC-25FPA, RAC-35FPA
- RAC-50FPA
- RAD-50PPA, RAD-60PPA, RAD-70PPA
- RAC-50DPA, RAC-60DPA, RAC-70DPA
- MONOZONE/MULTIZONE
- ELECTRICAL WIRING DIAGRAM
- 08_REFRIGERANT_CYCLE_ErP2013(done)
- REFRIGERANT CYCLE
- Monozone/Multizone Indoor Units
- Monozone/Multizone Outdoor Units
- MONO SPLIT
- WALL TYPE: RAK-18PSA/25PSA/35PSA / RAC-18WSA/25WSA/35WSA
- WALL TYPE: RAK-18PSAN/25PSAN/35PSAN / RAC-18WSAN/25WSAN/35WSAN
- WALL TYPE: RAK-18PSPA/25PSPA/35PSPA / RAC-18WSPA/25WSPA/35WSPA
- WALL TYPE: RAK-25PXA / RAC-25WXA
- WALL TYPE: RAK-35PXA / RAC-35WXA
- WALL TYPE: RAK-50PXA / RAC-50WXA
- WALL TYPE: RAK-18PPA/25PPA / RAC-18WPA/25WPA
- WALL TYPE: RAK-35PPA / RAC-35WPA
- WALL TYPE: RAK-50PPA / RAC-50WPA
- WALL TYPE: RAK-60PPA / RAC-60WPA
- WALL TYPE: RAK-70PPA / RAC-70WPA
- WALL TYPE: RAK-18PEA/25PEA / RAC-18WEA/25WEA
- WALL TYPE: RAK-35PEA / RAC-35WEA
- WALL TYPE: RAK-50PEA / RAC-50WEA
- FLOOR TYPE: RAF-25PXA/35PXA / RAC-25FXA/35FXA
- FLOOR TYPE: RAF-50PXA / RAC-50FXA
- FLOOR TYPE: RAF-25RPA / RAC-25FPA
- FLOOR TYPE: RAF-35RPA / RAC-35FPA
- FLOOR TYPE: RAF-50RPA / RAC-50FPA
- DUCT TYPE: RAD-50PPA/60PPA / RAC-50DPA/60DPA
- DUCT TYPE: RAD-70PPA / RAC-70DPA
- REFRIGERANT CYCLE
- 09_REMOTE_CONTROLLERS_OPERA-ErP2013(draft-03D)
- 10_UNITS_INSTALLATION-ErP2013(draft04A)
- UNITS INSTALLATION
- 10.1 INSTALLATION OF INDOOR UNIT
- INSTALLATION OF OUTDOOR UNIT
- FINAL STAGE OF INSTALLATION
- UNITS INSTALLATION
- 11_REFRIGERANT_PIPING_ErP2013(done)
- 12_DRAIN_PIPING_ErP2013(done)
- 13_ELECTRICAL_WIRING-ErP2013(draft01)
- ELECTRICAL WIRING
- General Check
- Electrical wiring for MONOZONE/MULTIZONE Unit
- Procedures of Wiring
- Electrical Wiring for Outdoor unit
- Electrical Wiring for Wall Type Indoor unit
- Electrical Wiring for Floor Type Indoor unit
- Electrical Wiring for 4 Way Ceiling Cassette Type Indoor unit (RAI-25RPA/RAI-35RPA/RAI-50RPA)
- Electrical Wiring for Duct Type Indoor unit (RAD-18RPA/RAD-25RPA/RAD-35RPA/RAD-50RPA/RAD-50PPA/RAD-60PPA/RAD-70PPA)
- Electrical wiring for SINGLE INVERTER Unit
- ELECTRICAL WIRING
- 14_TROUBLESHOOTING_ErP2013(done)
- TROUBLESHOOTING
- PRECAUTIONS FOR TROUBLE SHOOTING
- MONOZONE RAC-25NPA / 35NPA / 50NPA
- MULTIZONE RAM-36NP2A
- MULTIZONE/MONO SPLIT RAM-53NP2A / 53NP3A / 68NP3A / 70NP4A , MONO SPLIT RAF-50PXA/RAC-50FXA
- MULTIZONE RAM-90NP5A
- MULTIZONE RAM-130NP6A
- MONO SPLIT RAK-18/25/35PSA / RAC-18/25/35WSA , RAK-18/25/35PSAN / RAC-18/25/35WSAN , RAK-18/25/35PSPA / RAC-18/25/35WSPA
- MONO SPLIT RAK-18/25/35PPA / RAC-18/25/35WPA , RAK-18/25/35/50PEA / RAC-18/25/35/50WEA , RAF-25/35RPA / RAC-25/35FPA
- MONO SPLIT RAK-50/60/70PPA / RAC-50/60/70WPA
- MONO SPLIT RAF-50RPA / RAC-50FPA
- MONO SPLIT RAF-25/35PXA / RAC-25/35FXA
- MONO SPLIT RAD-50/60/70PPA / RAC-50/60/70DPA
- DISCHARGE PROCEDURE AND POWER SHUT OFF METHOD FOR POWER CIRCUIT
- MONOZONE RAC-25NPA / 35NPA / 50NPA & MULTIZONE RAM-36NP2A / 53NP2A / 53NP3A / 68NP3A / 70NP4A / 130NP6A & MONO SPLIT RAF-50PXA / RAC-50FXA, RAD-50/60/70PPA / RAC-50/60/70DPA
- MULTIZONE RAM-90NP5A
- MONO SPLIT RAK-18/25/35PSA / RAC-18/25/35WSA, RAK-18/25/35PSAN / RAC-18/25/35WSAN , RAK-18/25/35PSPA / RAC-18/25/35WSPA
- MONO SPLIT RAK-18/25/35PPA / RAC-18/25/35WPA, RAK-18/25/35/50PEA / RAC-18/25/35/50WEA , RAF-25/35PXA / RAC-25/35FXA RAF-50RPA / RAC-50FPA
- MONO SPLIT RAK-50/60/70PPA / RAC-50/60/70WPA
- MONO SPLIT RAF-25/35RPA / RAC-25/35FPA
- PRELIMINARY CHECK ON INDOOR/OUTDOOR UNIT ELECTRICAL PARTS AND REFRIGERATING
- CHECKING THE INDOOR UNIT ELECTRICAL PARTS
- No power is detected (no operation)
- Indoor fan does not operate (others are normal) – RAK-25/35/50PXA, RAK-18/25/35/50/70PPA, RAK-18/25/35/50PEA, RAF-25/35/50RPA, RAF-25/35/50PXA, RAD-50/60/70PPA
- Air deflector does not move (others are normal)
- Check the control P.W.B. (power circuit) – RAK-25/35PXA, RAK-18/25/35PPA, RAK-18/25/35/50PEA, RAF-25/35/50RPA, RAF-25/35PXA
- Checking the remote controller
- Outdoor unit does not operate (but receives remote infrared signal)
- All systems stop from several seconds to several minutes after operation is started (all indicators are also off)
- CHECKING OUTDOOR UNIT ELECTRICAL PARTS
- CHECKING BETWEEN GAS LEAKAGE AND COMPRESSOR FAULTY
- TROUBLESHOOTING WHEN INDOOR TIMER LAMP BLINKS
- TROUBLESHOOTING WHEN OUTDOOR LED LAMP BLINKS
- MONOZONE RAC-25NPA / 35NPA / 50NPA
- MULTIZONE
- COMMUNICATION ERROR DIAGNOSIS MULTIZONE RAM- 53NP3A / 68NP3A / 70NP4A / 130NP6A
- COMMUNICATION ERROR DIAGNOSIS MULTIZONE RAM-90NP5A
- MONO SPLIT(RAC-18/25/35WPA, RAC-25/35WXA, RAC-25/35FXA)
- MONO SPLIT (RAC-50WXA, RAC-50FXA
- MONO SPLIT (RAC-50/60/70WPA, RAC-50/60/70DPA)
- CHECKING POWER MODULE
- THERMISTOR
- PRECAUTIONS FOR TROUBLE SHOOTING
- TROUBLESHOOTING
- 15_MISC_Notes_split_ErP2013(done)
- MISCELLANEOUS NOTE
- INSTALLATION AT COLD REGIONS OR SNOWFALL REGIONS.
- INSTALLATION POINTS ON OUTDOOR UNITS IN COLD OR SNOWFALL REGIONS.
- Installation place of Cold and Snowfall Regions
- Considerations to the Seasonal Winds and Snowfall
- Considerations to Snowfall / Snow Buildup
- Considerations to Sliding Snow from Roof or SNOWFALL
- As to Proper Drainage of Defrosting WATER
- Request to cut Net attached to Rear side of Outdoor Unit
- Installation of HOT PIPE
- H-LINK ADAPTOR
- MISCELLANEOUS NOTE
- Back_page(new)
CAPACITIES AND SELECTION DATA
4-234
INDOOR
OUTDOOR TEMPERATURE (°CDW)
EDB
-15
-10
-7
-5
0
7
10
15
°C
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
(1.8+3.5)+(1.8
+1.8+3.5)
16
5040
0
2882
7980
0
2960
9097
0
3086
9842
0
3171
11984
0
3548
14154
0
3595
15442
0
3692
17822
0
3876
18
4970
0
2921
7910
0
2999
9010
0
3151
9744
0
3252
11858
0
3638
14084
0
3778
15386
0
3856
17752
0
4059
20
4900
0
2960
7840
0
3038
8932
0
3202
9660
0
3311
11760
0
3700
14000
0
3895
15050
0
4031
17640
0
4246
22
4830
0
2999
7770
0
3077
8820
0
3269
9520
0
3396
11634
0
3790
13916
0
4051
15218
0
4179
17556
0
4421
24
4760
0
3038
7700
0
3116
8742
0
3333
9436
0
3478
11536
0
3879
13832
0
4207
15134
0
4339
17304
0
4600
(1.8+5)+(1.8+
1.8+3.5)
16
5112
0
2923
8094
0
3002
9227
0
3130
9983
0
3215
12155
0
3598
14356
0
3646
15663
0
3745
18077
0
3930
18
5041
0
2963
8023
0
3042
9139
0
3196
9883
0
3298
12027
0
3689
14285
0
3832
15606
0
3911
18006
0
4116
20
4970
0
3002
7952
0
3081
9060
0
3247
9798
0
3358
11928
0
3753
14200
0
3950
15265
0
4088
17892
0
4306
22
4899
0
3042
7881
0
3121
8946
0
3315
9656
0
3444
11800
0
3843
14115
0
4108
15435
0
4238
17807
0
4483
24
4828
0
3081
7810
0
3160
8866
0
3380
9571
0
3527
11701
0
3934
14030
0
4266
15350
0
4400
17551
0
4665
(1.8+5)+(1.8+
1.8+5)
16
5112
0
2923
8094
0
3002
9227
0
3130
9983
0
3215
12155
0
3598
14356
0
3646
15663
0
3745
18077
0
3930
18
5041
0
2963
8023
0
3042
9139
0
3196
9883
0
3298
12027
0
3689
14285
0
3832
15606
0
3911
18006
0
4116
20
4970
0
3002
7952
0
3081
9060
0
3247
9798
0
3358
11928
0
3753
14200
0
3950
15265
0
4088
17892
0
4306
22
4899
0
3042
7881
0
3121
8946
0
3315
9656
0
3444
11800
0
3843
14115
0
4108
15435
0
4238
17807
0
4483
24
4828
0
3081
7810
0
3160
8866
0
3380
9571
0
3527
11701
0
3934
14030
0
4266
15350
0
4400
17551
0
4665
(2.5+2.5)+(1.8
+1.8+2.5)
16
5040
0
2897
7980
0
2975
9097
0
3102
9842
0
3187
11984
0
3567
14154
0
3614
15442
0
3711
17822
0
3895
18
4970
0
2936
7910
0
3015
9010
0
3167
9744
0
3269
11858
0
3657
14084
0
3798
15386
0
3876
17752
0
4079
20
4900
0
2975
7840
0
3054
8932
0
3218
9660
0
3328
11760
0
3719
14000
0
3915
15050
0
4052
17640
0
4267
22
4830
0
3015
7770
0
3093
8820
0
3285
9520
0
3414
11634
0
3809
13916
0
4072
15218
0
4201
17556
0
4444
24
4760
0
3054
7700
0
3132
8742
0
3350
9436
0
3496
11536
0
3899
13832
0
4228
15134
0
4361
17304
0
4624
(2.5+3.5)+(1.8
+1.8+2.5)
16
5112
0
2938
8094
0
3017
9227
0
3146
9983
0
3232
12155
0
3617
14356
0
3664
15663
0
3764
18077
0
3950
18
5041
0
2978
8023
0
3057
9139
0
3212
9883
0
3315
12027
0
3708
14285
0
3851
15606
0
3930
18006
0
4137
20
4970
0
3017
7952
0
3097
9060
0
3263
9798
0
3375
11928
0
3772
14200
0
3970
15265
0
4109
17892
0
4327
22
4899
0
3057
7881
0
3136
8946
0
3332
9656
0
3462
11800
0
3863
14115
0
4129
15435
0
4260
17807
0
4506
24
4828
0
3097
7810
0
3176
8866
0
3398
9571
0
3545
11701
0
3954
14030
0
4288
15350
0
4423
17551
0
4689
(1.8+5)+(1.8+
2.5+2.5)
16
5112
0
2923
8094
0
3002
9227
0
3130
9983
0
3215
12155
0
3598
14356
0
3646
15663
0
3745
18077
0
3930
18
5041
0
2963
8023
0
3042
9139
0
3196
9883
0
3298
12027
0
3689
14285
0
3832
15606
0
3911
18006
0
4116
20
4970
0
3002
7952
0
3081
9060
0
3247
9798
0
3358
11928
0
3753
14200
0
3950
15265
0
4088
17892
0
4306
22
4899
0
3042
7881
0
3121
8946
0
3315
9656
0
3444
11800
0
3843
14115
0
4108
15435
0
4238
17807
0
4483
24
4828
0
3081
7810
0
3160
8866
0
3380
9571
0
3527
11701
0
3934
14030
0
4266
15350
0
4400
17551
0
4665
(3.5+3.5)+(1.8
+1.8+2.5)
16
5184
0
2967
8208
0
3048
9357
0
3178
10123
0
3264
12326
0
3653
14558
0
3701
15883
0
3801
18331
0
3990
18
5112
0
3008
8136
0
3088
9268
0
3244
10022
0
3348
12197
0
3745
14486
0
3890
15826
0
3970
18259
0
4178
20
5040
0
3048
8064
0
3128
9187
0
3296
9936
0
3409
12096
0
3810
14400
0
4010
15480
0
4150
18144
0
4371
22
4968
0
3088
7992
0
3168
9072
0
3365
9792
0
3497
11966
0
3902
14314
0
4170
15653
0
4303
18058
0
4551
24
4896
0
3128
7920
0
3208
8991
0
3432
9706
0
3581
11866
0
3994
14227
0
4331
15566
0
4467
17798
0
4736
(1.8+5)+(1.8+
2.5+3.5)
16
5112
0
2923
8094
0
3002
9227
0
3130
9983
0
3215
12155
0
3598
14356
0
3646
15663
0
3745
18077
0
3930
18
5041
0
2963
8023
0
3042
9139
0
3196
9883
0
3298
12027
0
3689
14285
0
3832
15606
0
3911
18006
0
4116
20
4970
0
3002
7952
0
3081
9060
0
3247
9798
0
3358
11928
0
3753
14200
0
3950
15265
0
4088
17892
0
4306
22
4899
0
3042
7881
0
3121
8946
0
3315
9656
0
3444
11800
0
3843
14115
0
4108
15435
0
4238
17807
0
4483
24
4828
0
3081
7810
0
3160
8866
0
3380
9571
0
3527
11701
0
3934
14030
0
4266
15350
0
4400
17551
0
4665
EWB : Evaporator Wet Bulb temperature (°C)
TC : Total Capacity (W)
EDB : Evaporator Dry Bulb temperature (°C)
SHC : Sensible Heating Capacity (W)
(°CDB) : Outdoor Unit Inlet Air Dry Temperature (°C)
PI : Power Input